Log entry time 18:55:57 on June 22, 2004
Entry number 126658
keyword=End_of_Parity_Run_2375__CODA_Config=Beamline
************************************************
Run Number: 2375
End of Run Comment:
Run_type=other,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=injector studies, 50 uA in 100 keV, RHWP scan with PITA=+100V,leftarm_p=3.009,leftarm_theta=6,parity_feedback=off,parity_ihwp=out,rightarm_p=3.005,rightarm_theta=6,target_fanspeed=48,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 2375 at Tue Jun 22 18:55:05 EDT 2004
CODA Configuration: Beamline
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 369.04
Wien field : 10.527
Laser attenuation Hall A : 220
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2250
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 7.072
Gun3: PC (PITA) NEG : 4.721
Pockels Cell Voltage POS : 2.81319
Pockels Cell Voltage NEG : 2.56899
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -2.7
LUMI HV - Ch 1 : -3.1
LUMI HV - Ch 2 : -1.7
LUMI HV - Ch 3 : -2.6
LUMI HV - Ch 4 : -2.2
LUMI HV - Ch 5 : -2.3
LUMI HV - Ch 6 : -2.6
LUMI HV - Ch 7 : -2.2
LUMI HV - Ch 8 : -18.7
LUMI HV - Ch 9 : -19.4
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -15.2
HAPPEX Detector2 HV - Left Slot10 Ch10 : -18.9
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -15.3
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -21.4
Scanner Left HV - Left Slot10 Ch11 : -18
Scanner Right HV - RightB Slot10 Ch11 : -21.4
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 0
Left septum current readback : -2.5
Left septum upper coil T : 6.25
Left septum lower coil T : 6.4
Left septum yoke T : 4.85
Left septum bore shield T : 81.5
Left Arm Q1 power supply current : 1806.9
Left Arm Q1 momentum : 3.00901
Left Arm Q1 gauss meter : -0.15249
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1305.51
Left Arm Q2 momentum : 3.00844
Left Arm Q2 gauss meter : 0.6876
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1055.41
Left Arm D1 momentum : 3.009
Left Arm D1 NMR : 1.11418
Left Arm Q3 power supply current : 1409.08
Left Arm Q3 momentum : 3.00899
Left Arm Q3 gauss meter : -0.7048
Left Arm Q3 power supply polarity : disabled
Right septum set current : 0
Right septum current readback : 0
Right septum upper coil T : 7.25
Right septum lower coil T : 6.9
Right septum yoke T : 5.6
Right septum bore shield T : 10.25
Right Arm Q1 power supply current : 1796.38
Right Arm Q1 momentum : 3.00504
Right Arm Q1 gauss meter : -0.04441
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1304.07
Right Arm Q2 momentum : 3.00512
Right Arm Q2 gauss meter : 0.6847
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1079.97
Right Arm D1 momentum : 3.005
Right Arm D1 NMR : 1.11512
Right Arm Q3 power supply current : 1407.26
Right Arm Q3 momentum : 3.0051
Right Arm Q3 gauss meter : 0.6316
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.537109
Left Arm Bottom VDC Current : 0.634766
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : -0.732422
Left Arm Top VDC voltage : 0.00976562
Left Arm Bottom VDC voltage : 0.0102539
Right Arm Top VDC voltage : -0.00537109
Right Arm Bottom VDC voltage : -0.00439453
Average current of the two cavities : 0.0445189
Current on Unser monitor : -3.8435
Current on Upstream bcm : 0.031
Current on Downstream bcm : 0.0580378
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.001435
Tiefenbach Hall A energy : 3028.47
Tiefenbach Hall C energy : 2038.06
Delta(E)/E width (MV_AI_DXWID) : 12.3464
MBSY1c Hall A Beam energy : 3033.17
MBSY3c Hall C Beam energy : 2042.63
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 756932
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.057959
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127374
HacL_HPE1313A:0_Ch58 : -0.178223
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : 0.0380859
HacL_alignROLL : 0.376945
HacL_alignPITCH : -0.106057
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000634766
Right LVDT HPM : 3288
Right LVDT VPM : 3877
HacR_HPE1313A:0_Ch58 : -0.542969
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.890137
HacR_alignROLL : -0.41174
HacR_alignPITCH : -0.0121411
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 9075343
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 94.98
temperature loop 2-2 : 94.98
temperature loop 2-3 : 94.98
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 22.7268
pressure loop H2 : 23.2441
No HAPPEX feedback runlog entry for Run #2375
Was feedback on?