    User name apar

    Log entry time 17:01:56 on June 24, 2004

    Entry number 126687

    keyword=Start_Parity_Run_2384__CODA_Config=happex2_Run_type=other,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=scanner positions calibration, and detector pedestal check,leftarm_p=3.009,leftarm_theta=6,parity_feedback=off,parity_ihwp=in,rightarm_p=3.005,rightarm_theta=6,target_fanspeed=48,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 2384 at Thu Jun 24 17:01:06 EDT 2004
    CODA Configuration: happex2
    
    # Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
    
    Wien angle                               : 15.9458
    Wien BDL                                 : 369.04
    Wien field                               : 10.527
    Laser attenuation Hall A                 : 100
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 6500
    IA Cell Setpoint  Hall A                 : 5
    PZT X Setpoint  Hall A                   : 5
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5
    Gun2: PC (PITA) NEG                      : 5
    Gun3: PC (PITA) POS                      : 3.931
    Gun3: PC (PITA) NEG                      : 6.658
    Pockels Cell Voltage POS                 : 2.60806
    Pockels Cell Voltage NEG                 : 2.68376
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : No Delay
    G0 Helicity Pattern Set                  : Pair
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : No Delay
    G0 Helicity Pattern Read                 : Pair
    G0 Helicity Random/Toggle Read           : Random
    Parity DAQ Feedback Control(1=on)        : 0
    LUMI HV - Ch  0                          : -2.7
    LUMI HV - Ch  1                          : -3.1
    LUMI HV - Ch  2                          : -1.7
    LUMI HV - Ch  3                          : -2.6
    LUMI HV - Ch  4                          : -2.2
    LUMI HV - Ch  5                          : -2.3
    LUMI HV - Ch  6                          : -2.6
    LUMI HV - Ch  7                          : -2.2
    LUMI HV - Ch  8                          : -3.4
    LUMI HV - Ch  9                          : -4.1
    LUMI HV - Ch  10                         : -18.3
    LUMI HV - Ch  11                         : -12.3
    HAPPEX Detector1 HV - Left Slot10 Ch9    : -1201.2
    HAPPEX Detector2 HV - Left Slot10 Ch10   : -1200.7
    HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1200.7
    HAPPEX Detector4 HV - RightB Slot10 Ch9  : -1201.9
    Scanner Left HV - Left Slot10 Ch11       : -1550.5
    Scanner Right HV - RightB Slot10 Ch11    : -1550.1
    Left Arm arm angle                       : 12.321
    Right Arm arm angle                      : 12.697
    Left Arm arm mispointing (HPT)           : -0
    Right Arm arm mispointing (HPT)          : -0
    Left septum set current                  : 247.93
    Left septum current readback             : 141
    Left septum upper coil T                 : 6.4
    Left septum lower coil T                 : 6.15
    Left septum yoke T                       : 4.75
    Left septum bore shield  T               : 81.65
    Left Arm Q1 power supply current         : 517.884
    Left Arm Q1 momentum                     : 0.854953
    Left Arm Q1 gauss meter                  : -0.04355
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1162.09
    Left Arm Q2 momentum                     : 2.67793
    Left Arm Q2 gauss meter                  : 0.6125
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 268.247
    Left Arm D1 momentum                     : 0
    Left Arm D1 NMR                          : 0.671199
    Left Arm Q3 power supply current         : 1254.13
    Left Arm Q3 momentum                     : 2.67812
    Left Arm Q3 gauss meter                  : -0.6274
    Left Arm Q3 power supply polarity        : disabled
    Right septum set current                 : 247.93
    Right septum current readback            : 211.75
    Right septum upper coil T                : 6
    Right septum lower coil T                : 6.25
    Right septum yoke T                      : 5.1
    Right septum bore shield  T              : 8.5
    Right Arm Q1 power supply current        : 896.696
    Right Arm Q1 momentum                    : 1.50002
    Right Arm Q1 gauss meter                 : -0.022351
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1399.97
    Right Arm Q2 momentum                    : 3.2261
    Right Arm Q2 gauss meter                 : 0.7349
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 341.842
    Right Arm D1 momentum                    : 0.878058
    Right Arm D1 NMR                         : 0.325837
    Right Arm Q3 power supply current        : 1400.04
    Right Arm Q3 momentum                    : 2.98968
    Right Arm Q3 gauss meter                 : 0.6281
    Right Arm Q3 power supply polarity       : disabled
    Left Arm Top VDC Current                 : 0.585938
    Left Arm Bottom VDC Current              : 0.634766
    Right Arm Top VDC Current                : -0.78125
    Right Arm Bottom VDC Current             : -0.683594
    Left Arm Top VDC voltage                 : 0.00976562
    Left Arm Bottom VDC voltage              : 0.0102539
    Right Arm Top VDC voltage                : -0.00537109
    Right Arm Bottom VDC voltage             : -0.00488281
    Average current of the two cavities      : 0.0438755
    Current on Unser monitor                 : 9.87035
    Current on Upstream bcm                  : 0.0306749
    Current on Downstream bcm                : 0.0570761
    Upstream Cavity Coefficient              : 76.7
    Downstream Cavity Coefficient            : 78.9
    Current on IBC0L02 (source)              : 0.001435
    Tiefenbach Hall A energy                 : 3028.47
    Tiefenbach Hall C energy                 : 5009.4
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3033.17
    MBSY3c Hall C Beam energy                : 5024.97
    MBSY1c magnet current (amp)              : 0.0377198
    MBSY1c Bdl                               : 756932
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.057373
    Left LVDT HPM                            : 3.441e+19
    Left LVDT VPM                            : -127383
    HacL_HPE1313A:0_Ch58                     : -0.180664
    HacL_HPE1313A:0_Ch55                     : 23.1445
    HacL_HPE1313A:0_Ch54                     : 0.0415039
    HacL_alignROLL                           : 0.380352
    HacL_alignPITCH                          : -0.103142
    HacL_alignHPT                            : -0
    Left Arm Angle Floor Angle               : 12.5
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : 12.321
    Right Arm Collimator                     : -0.000537109
    Right LVDT HPM                           : 3288
    Right LVDT VPM                           : 3864
    HacR_HPE1313A:0_Ch58                     : -0.547363
    HacR_HPE1313A:0_Ch55                     : 21.9238
    HacR_HPE1313A:0_Ch54                     : -0.896484
    HacR_alignROLL                           : -0.417273
    HacR_alignPITCH                          : -0.00796992
    HacR_alignHPT                            : -0
    Right Arm Angle Floor Angle              : 12.5
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 12.697
    Arc OTR  x-position                      : 0.660411
    Arc OTR  y-position                      : 2.0866
    Arc OTR  x-width                         : 0.629421
    Arc OTR  y-width                         : 0.662522
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : Sources adc bin bob crl doc lib pan tmp tst
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 60
    fan frequency loop 3                     : 0
    Encoder position                         : 52359
    temperature loop 1-1                     : 93.8
    temperature loop 1-2                     : 99.99
    temperature loop 1-3                     : 92.83
    temperature loop 2-1                     : 18.99
    temperature loop 2-2                     : 18.99
    temperature loop 2-3                     : 18.91
    temperature loop 3-1                     : 94.98
    temperature loop 3-2                     : 94.98
    temperature loop 3-3                     : 94.98
    pressure loop D2                         : 26.6148
    pressure loop H2                         : 19.91
    
    Parameters used for HAPPEX feedback
    anatype fdbk
    curmon bcm3
    feedback IA on 2 bcm3
    feedback PZT onc 20 bpm4b
    IAparam slope -154.3