    User name a-onl

    Log entry time 21:37:32 on June 24, 2004

    Entry number 126711

    keyword=End_of_Run_1164
    ****************************
     Run Number: 1164
     End of Run Comment:
    Run_type=alignment,beam_energy=3.0282,beam_halfwaveplate=in,beam_raster=on,comment_text=alignment of profile scanner,daq_mode=TWOARM,kin_name=,leftarm_p=2.678,leftarm_theta=6,rightarm_p=2.678,rightarm_theta=6,target_type=Hydrogen
    Not happy with prescale factors.  Try again.  Also, not sure scanner is in right position (in acceptance)
    and UMass/Smith folks are moving it.
     
    
    PRESCALE FACTORS:ps1=716   ps2=90   ps3=670   ps4=107   ps5=60   ps6=53   ps7=65535   ps8=65535   
    
    EVENTS[0]: 152976       [+]: 152976       [-]: 0            
    TIME  [0]: 1.946 mins  [+]: 2.263 mins  [-]: 0.017 mins  
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  86.18%      [+]:  74.27%      [-]: 100.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :305.6/218786.5 Hz   T2[0] :313.5/28217.4 Hz   T3[0] :301.6/202044.5 Hz   T4[0] :293.0/31351.2 Hz   T5[0] :288.8/17330.0 Hz   T6[0] :18.5/981.1 Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :304.8/218214.3 Hz   T2[+] :312.6/28137.9 Hz   T3[+] :300.7/201492.0 Hz   T4[+] :292.2/31268.3 Hz   T5[+] :288.8/17329.6 Hz   T6[+] :18.5/978.9 Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 0.0/0.0  Hz   T2[-] : 0.0/0.0  Hz   T3[-] : 0.0/0.0  Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 0.0/0.0  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  35681/25548029  T2[0] :  36610/3294984  T3[0] :  35213/23593031  T4[0] :  34214/3660926  T5[0] :  33727/2023653  T6[0] :   2161/114569   T7[0] :      0/0        T8[0] :      1/119574   
    T1[+] :  41382/29629835  T2[+] :  42451/3820654  T3[+] :  40834/27359229  T4[+] :  39679/4245708  T5[+] :  39217/2353067  T6[+] :   2507/132923   T7[+] :      0/0        T8[+] :      2/139042   
    T1[-] :      0/0        T2[-] :      0/0        T3[-] :      0/0        T4[-] :      0/0        T5[-] :      0/0        T6[-] :      0/0        T7[-] :      0/0        T8[-] :      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 0.6530 uA  BCM x3 : -0.0213uA  BCM x10: 0.5247 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :1.395E+06 ppm     BCM u3 :    1E+39 ppm     BCM u10:1.111E+06 ppm     
    BCM d1 :1.088E+06 ppm     BCM d3 :    1E+39 ppm     BCM d10:1.099E+06 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:8.151E-05      BCM u3 [0]:-3.132E-06     BCM u10[0]:6.473E-05      
    BCM u1 [+]:9.459E-05      BCM u3 [+]:-3.641E-06     BCM u10[+]:7.506E-05      
    BCM u1 [-]:-1.149E-07     BCM u3 [-]:-4.003E-08     BCM u10[-]:-2.898E-08     
    
    BCM d1 [0]:7.101E-05      BCM d3 [0]:-1.838E-06     BCM d10[0]:5.781E-05      
    BCM d1 [+]:8.237E-05      BCM d3 [+]:-2.138E-06     BCM d10[+]:6.704E-05      
    BCM d1 [-]:-2.559E-08     BCM d3 [-]:-2.627E-08     BCM d10[-]:-2.334E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1164 at Thu Jun 24 21:37:19 EDT 2004
    Left Arm D1 momentum : 2.678
    Left Arm arm angle : 12.321
    Right Arm D1 momentum : 2.67799
    Right Arm arm angle : 12.697
    HALLA:p : 3028.32
    HALLA:dpp : -5.13157e-05
    Tiefenbach Hall A energy : 3028.31
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.683594
    Left Arm Bottom VDC Current : 0.732422
    Left septum set current : 0
    Left septum current readback : 248.5
    Left septum upper coil T : 6.4
    Left septum lower coil T : 6.15
    Left septum yoke T : 4.75
    Left septum bore shield T : 81.65
    Left Arm Q1 momentum : 2.67799
    Left Arm Q2 power supply current : 1162.14
    Left Arm Q2 momentum : 2.67804
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 929.171
    Left Arm D1 momentum : 2.678
    Left Arm D1 NMR : 0.99136
    Left Arm Q3 power supply current : 1254.09
    Left Arm Q3 momentum : 2.67802
    Left Arm Q3 power supply polarity : disabled
    Right septum set current : 248.3
    Right septum current readback : 247.5
    Right septum upper coil T : 6
    Right septum lower coil T : 6.25
    Right septum yoke T : 5.1
    Right septum bore shield T : 8.5
    Right Arm Q1 momentum : 2.67806
    Right Arm Q1 gauss meter : -0.03963
    Right Arm Q2 power supply current : 1161.98
    Right Arm Q2 momentum : 2.67769
    Right Arm Q2 gauss meter : 0.6104
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 950.628
    Right Arm D1 momentum : 2.678
    Right Arm D1 NMR : 0.993773
    Right Arm Q3 power supply current : 1254.04
    Right Arm Q3 momentum : 2.67792
    Right Arm Q3 gauss meter : 0.5628
    Right Arm Q3 power supply polarity : disabled
    RICH Vmon 16 : 0
    RICH Imon 16 : 0
    RICH Vmon 17 : 0
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.976562
    RICH Radiator Moisture : -1.07422
    RICH Radiator Pressure : 0.634766
    RICH Condensor temperature : 20.2617
    RICH Gas Oxygen : -0.976562
    RICH Gas Moisture : -1.07422
    RICH Argon Flow : 5.76172
    RICH Methane Flow : 0.878906
    RICH A Volts : 0.364746
    RICH B Volts : 0.198242