    User name a-onl

    Log entry time 23:09:07 on June 24, 2004

    Entry number 126742

    keyword=Start_Run_1174,Run_type=alignment,beam_energy=3.0282,beam_halfwaveplate=in,beam_raster=on,comment_text=alignment of profile scanner,daq_mode=TWOARM,kin_name=,leftarm_p=2.678,leftarm_theta=6,rightarm_p=2.678,rightarm_theta=6,target_type=Hydrogen
    Beginning-of-run EPICS data for Run Number 1174 at Thu Jun 24 23:08:53 EDT 2004
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; The default factor is essentially infinite. 
    ; PS1 for R-arm S2m scintillator trigger ("or" of S2m)
    ; PS2 for R-arm HAPPEX electron calorimeter trigger
    ; PS3 for L-arm S2m scintillator trigger ("or" of S2m).
    ; PS4 for L-arm HAPPEX electron calorimeter trigger
    ; PS5 for R-arm UMass/Smith Q^2 Profile Scanner PMT
    ; PS6 for L-arm UMass/Smith Q^2 Profile Scanner PMT
    ; PS8 for 1024 Hz pulser ( put ps=65535 normally or =4 for spot++ check )
    
    ps1=716,ps2=90,ps3=670,ps4=107,ps5=2300,ps6=276,ps7=65535,ps8=65535
     
    Left septum set current : 248.25
    Left septum current readback : 248
    Left septum upper coil T : 6.4
    Left septum lower coil T : 6.15
    Left septum yoke T : 4.75
    Left septum bore shield T : 81.65
    Left Arm Q1 momentum : 2.6779
    Left Arm Q2 power supply current : 1162.3
    Left Arm Q2 momentum : 2.67842
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 929.173
    Left Arm D1 momentum : 2.67801
    Left Arm D1 NMR : 0.991361
    Left Arm Q3 power supply current : 1254.01
    Left Arm Q3 momentum : 2.67784
    Left Arm Q3 power supply polarity : disabled
    Right septum set current : 248.25
    Right septum current readback : 247.5
    Right septum upper coil T : 6
    Right septum lower coil T : 6.25
    Right septum yoke T : 5.1
    Right septum bore shield T : 8.5
    Right Arm Q1 momentum : 2.67797
    Right Arm Q1 gauss meter : -0.03964
    Right Arm Q2 power supply current : 1162.07
    Right Arm Q2 momentum : 2.67789
    Right Arm Q2 gauss meter : 0.6104
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 950.629
    Right Arm D1 momentum : 2.678
    Right Arm D1 NMR : 0.993773
    Right Arm Q3 power supply current : 1254.28
    Right Arm Q3 momentum : 2.67842
    Right Arm Q3 gauss meter : 0.5628
    Right Arm Q3 power supply polarity : disabled
    Right Arm Top VDC voltage : 3.99512
    Right Arm Bottom VDC voltage : 3.99756
    Average current of the two cavities : 0.507374
    Current on Unser monitor : 10.9781
    Current on Upstream bcm : 0.552029
    Current on Downstream bcm : 0.462719
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.71579
    Tiefenbach Hall A energy : 3028.31
    Tiefenbach Hall C energy : 5009.4
    Delta(E)/E width (MV_AI_DXWID) : 5.29639
    HALLA:p : 3028.31
    HALLA:dpp : -5.55726e-05
    MBSY1c Hall A Beam energy : 3033.17
    MBSY3c Hall C Beam energy : 5024.97
    MBSY1c magnet current (amp) : 126.281
    MBSY1c Bdl : 756932
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0.263723
    IPM1H04A.YPOS : 0.168237
    IPM1H04B.XPOS : -0.80397
    IPM1H04B.YPOS : 0.251078
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 15.9458
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 369.04
    Wien field : 10.527
    Laser attenuation Hall A : 100
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 6500
    Beam Half-wave plate (off=out) : IN
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Pair
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Pair
    RICH Vmon 16 : 0
    RICH Vmon 16 : 0
    RICH Imon 16 : 0
    RICH Imon 16 : 0
    RICH Vmon 17 : 0
    RICH Vmon 17 : 0
    RICH Imon 17 : 0
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.878906
    RICH Radiator Oxygen : -0.878906
    RICH Radiator Moisture : -1.07422
    RICH Radiator Moisture : -1.07422
    RICH Radiator Pressure : 0.632812
    RICH Radiator Pressure : 0.632812
    RICH Condensor temperature : 19.9199
    RICH Condensor temperature : 19.9199
    RICH Gas Oxygen : -1.07422
    RICH Gas Oxygen : -1.07422
    RICH Gas Moisture : -0.976562
    RICH Gas Moisture : -0.976562
    RICH Argon Flow : 6.05469
    RICH Argon Flow : 6.05469
    RICH Methane Flow : 0.878906
    RICH Methane Flow : 0.878906
    RICH A Volts : 0.364258
    RICH A Volts : 0.364258
    RICH B Volts : 0.19873
    RICH B Volts : 0.19873