User name apar
Log entry time 10:16:16 on June 25, 2004
Entry number 126816
keyword=Start_Parity_Run_2398__CODA_Config=happex2_Run_type=production,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=30 uA, Production,leftarm_p=2.974,leftarm_theta=6,parity_feedback=on,parity_ihwp=in,rightarm_p=2.964,rightarm_theta=6,target_fanspeed=60,target_type=20cm LH2
Beginning-of-Parity-run EPICS data for Run Number 2398 at Fri Jun 25 10:15:26 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 369.04
Wien field : 10.527
Laser attenuation Hall A : 281
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6500
IA Cell Setpoint Hall A : 6.14
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 3.931
Gun3: PC (PITA) NEG : 6.658
Pockels Cell Voltage POS : 2.60317
Pockels Cell Voltage NEG : 2.68132
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -424.7
LUMI HV - Ch 1 : -850.9
LUMI HV - Ch 2 : -475.6
LUMI HV - Ch 3 : -424.7
LUMI HV - Ch 4 : -484
LUMI HV - Ch 5 : -399.9
LUMI HV - Ch 6 : -425.6
LUMI HV - Ch 7 : -426.8
LUMI HV - Ch 8 : -525.4
LUMI HV - Ch 9 : -626.7
LUMI HV - Ch 10 : -10.7
LUMI HV - Ch 11 : -12.3
HAPPEX Detector1 HV - Left Slot10 Ch9 : -1320.8
HAPPEX Detector2 HV - Left Slot10 Ch10 : -1270.4
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1210.9
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -1462.3
Scanner Left HV - Left Slot10 Ch11 : -2.8
Scanner Right HV - RightB Slot10 Ch11 : -3.9
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 275.8
Left septum current readback : 275.25
Left septum upper coil T : 6.4
Left septum lower coil T : 6.55
Left septum yoke T : 4.85
Left septum bore shield T : 80.3
Left Arm Q1 power supply current : 1785.97
Left Arm Q1 momentum : 2.97406
Left Arm Q1 gauss meter : -0.15072
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1290.64
Left Arm Q2 momentum : 2.97417
Left Arm Q2 gauss meter : 0.6798
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1042.11
Left Arm D1 momentum : 2.97401
Left Arm D1 NMR : 1.1012
Left Arm Q3 power supply current : 1392.75
Left Arm Q3 momentum : 2.97411
Left Arm Q3 gauss meter : -0.6966
Left Arm Q3 power supply polarity : disabled
Right septum set current : 276
Right septum current readback : 274.75
Right septum upper coil T : 7
Right septum lower coil T : 6.75
Right septum yoke T : 5.7
Right septum bore shield T : 73.15
Right Arm Q1 power supply current : 1771.76
Right Arm Q1 momentum : 2.96394
Right Arm Q1 gauss meter : -0.04386
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1286.07
Right Arm Q2 momentum : 2.96364
Right Arm Q2 gauss meter : 0.6754
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1063.22
Right Arm D1 momentum : 2.96399
Right Arm D1 NMR : 1.0999
Right Arm Q3 power supply current : 1387.76
Right Arm Q3 momentum : 2.96347
Right Arm Q3 gauss meter : 0.6227
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.732422
Left Arm Bottom VDC Current : 0.732422
Right Arm Top VDC Current : -0.732422
Right Arm Bottom VDC Current : -0.683594
Left Arm Top VDC voltage : 0.0102539
Left Arm Bottom VDC voltage : 0.0107422
Right Arm Top VDC voltage : -0.00585938
Right Arm Bottom VDC voltage : -0.00488281
Average current of the two cavities : 20.4989
Current on Unser monitor : 37.5884
Current on Upstream bcm : 21.6329
Current on Downstream bcm : 19.3649
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 39.5758
Tiefenbach Hall A energy : 3026.9
Tiefenbach Hall C energy : 5009.12
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3032.05
MBSY3c Hall C Beam energy : 5023.69
MBSY1c magnet current (amp) : 126.234
MBSY1c Bdl : 756652
IPM1C12.XPOS : -0.00403574
IPM1C12.YPOS : 0.120271
IPM1H04A.XPOS : 0.43674
IPM1H04A.YPOS : -0.146261
IPM1H04B.XPOS : -0.0323617
IPM1H04B.YPOS : -0.00109589
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0579102
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127374
HacL_HPE1313A:0_Ch58 : -0.179688
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.034668
HacL_alignROLL : 0.373924
HacL_alignPITCH : -0.104526
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000292969
Right LVDT HPM : 3288
Right LVDT VPM : 3876
HacR_HPE1313A:0_Ch58 : -0.546387
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.893555
HacR_alignROLL : -0.414865
HacR_alignPITCH : -0.00924984
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 0
fan frequency loop 2 : 62
fan frequency loop 3 : 0
Encoder position : 25329284
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 19
temperature loop 2-2 : 18.99
temperature loop 2-3 : 19.04
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 25.9571
pressure loop H2 : 20.3433
Parameters used for HAPPEX feedback
anatype fdbk
curmon bcm3
feedback IA on 2 bcm3
feedback PZT onc 20 bpm4b
IAparam slope -154.3