Log entry time 06:12:06 on June 28, 2004
Entry number 127187
keyword=Start_Parity_Run_2492__CODA_Config=happex2_Run_type=production,beam_energy=3.028,beam_polarization=86.0,beam_raster=on,comment_text=production,leftarm_p=2.971,leftarm_theta=6,parity_feedback=on,parity_ihwp=in,rightarm_p=2.960,rightarm_theta=6,target_fanspeed=60,target_type=20cm LH2
Beginning-of-Parity-run EPICS data for Run Number 2492 at Mon Jun 28 06:11:15 EDT 2004
CODA Configuration: happex2
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 15.9458
Wien BDL : 369.04
Wien field : 10.527
Laser attenuation Hall A : 343
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6500
IA Cell Setpoint Hall A : 5.46
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5
Gun2: PC (PITA) NEG : 5
Gun3: PC (PITA) POS : 4.7
Gun3: PC (PITA) NEG : 5.889
Pockels Cell Voltage POS : 2.6569
Pockels Cell Voltage NEG : 2.63736
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
LUMI HV - Ch 0 : -449.9
LUMI HV - Ch 1 : -850.9
LUMI HV - Ch 2 : -495.3
LUMI HV - Ch 3 : -450
LUMI HV - Ch 4 : -513
LUMI HV - Ch 5 : -430.3
LUMI HV - Ch 6 : -450.8
LUMI HV - Ch 7 : -432.1
LUMI HV - Ch 8 : -555.2
LUMI HV - Ch 9 : -635.9
LUMI HV - Ch 10 : -10.7
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -1301
HAPPEX Detector2 HV - Left Slot10 Ch10 : -1291.1
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -1210.9
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -1502
Scanner Left HV - Left Slot10 Ch11 : -3.6
Scanner Right HV - RightB Slot10 Ch11 : -4.7
Left Arm arm angle : 12.321
Right Arm arm angle : 12.697
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left septum set current : 275.5
Left septum current readback : 275.25
Left septum upper coil T : 6.85
Left septum lower coil T : 7.05
Left septum yoke T : 5.15
Left septum bore shield T : 80.45
Left Arm Q1 power supply current : 1784.05
Left Arm Q1 momentum : 2.97095
Left Arm Q1 gauss meter : -0.15056
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1289.3
Left Arm Q2 momentum : 2.97107
Left Arm Q2 gauss meter : 0.679
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1040.98
Left Arm D1 momentum : 2.97099
Left Arm D1 NMR : 1.10008
Left Arm Q3 power supply current : 1391.24
Left Arm Q3 momentum : 2.9709
Left Arm Q3 gauss meter : -0.6959
Left Arm Q3 power supply polarity : disabled
Right septum set current : 275.35
Right septum current readback : 274.25
Right septum upper coil T : 7.6
Right septum lower coil T : 7.4
Right septum yoke T : 6.15
Right septum bore shield T : 73.15
Right Arm Q1 power supply current : 1769.47
Right Arm Q1 momentum : 2.96001
Right Arm Q1 gauss meter : -0.04376
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1284.48
Right Arm Q2 momentum : 2.95998
Right Arm Q2 gauss meter : 0.6746
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1061.47
Right Arm D1 momentum : 2.96
Right Arm D1 NMR : 1.09842
Right Arm Q3 power supply current : 1386.22
Right Arm Q3 momentum : 2.96018
Right Arm Q3 gauss meter : 0.6219
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 0.634766
Left Arm Bottom VDC Current : 0.634766
Right Arm Top VDC Current : -0.78125
Right Arm Bottom VDC Current : -0.830078
Left Arm Top VDC voltage : 0.0102539
Left Arm Bottom VDC voltage : 0.0102539
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.00488281
Average current of the two cavities : 33.9441
Current on Unser monitor : 23.1592
Current on Upstream bcm : 33.5768
Current on Downstream bcm : 34.3113
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 106.974
Tiefenbach Hall A energy : 3028.51
Tiefenbach Hall C energy : 5010.59
Delta(E)/E width (MV_AI_DXWID) : 3.39539
MBSY1c Hall A Beam energy : 3033.65
MBSY3c Hall C Beam energy : 5025.29
MBSY1c magnet current (amp) : 126.301
MBSY1c Bdl : 757052
IPM1C12.XPOS : -0.00912821
IPM1C12.YPOS : 0.139688
IPM1H04A.XPOS : 0.175998
IPM1H04A.YPOS : -0.140556
IPM1H04B.XPOS : 0.0738037
IPM1H04B.YPOS : -0.000847459
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0579102
Left LVDT HPM : 3.441e+19
Left LVDT VPM : -127374
HacL_HPE1313A:0_Ch58 : -0.180664
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0297852
HacL_alignROLL : 0.372143
HacL_alignPITCH : -0.104163
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : 12.321
Right Arm Collimator : -0.000585938
Right LVDT HPM : 3288
Right LVDT VPM : 3875
HacR_HPE1313A:0_Ch58 : -0.54541
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.89502
HacR_alignROLL : -0.416287
HacR_alignPITCH : -0.00931609
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 12.697
Arc OTR x-position : 0.660411
Arc OTR y-position : 2.0866
Arc OTR x-width : 0.629421
Arc OTR y-width : 0.662522
Arc OTR data valid flag : No
Arc OTR In/Out : Sources adc bin bob crl doc lib pan tmp tst
fan frequency loop 1 : 0
fan frequency loop 2 : 65.5
fan frequency loop 3 : 0
Encoder position : 25329284
temperature loop 1-1 : 93.8
temperature loop 1-2 : 99.99
temperature loop 1-3 : 92.83
temperature loop 2-1 : 19
temperature loop 2-2 : 19
temperature loop 2-3 : 19.12
temperature loop 3-1 : 94.98
temperature loop 3-2 : 94.98
temperature loop 3-3 : 94.98
pressure loop D2 : 24.9744
pressure loop H2 : 20.6256
Parameters used for HAPPEX feedback
anatype fdbk
curmon bcm3
feedback IA on 2 bcm3
feedback PZT onc 20 bpm4b
IAparam slope -154.3