    User name X. Zheng

    Log entry time 00:01:25 on July 1,2004

    Entry number 127565

    keyword=shift summary

    16:20-30 did a quick harp scan test. However, forgot to end run 2564. 16:30 back to normal production running. The beam current is 26 uA instead of the 35 uA we asked.
    16:50 spot move to increase the current to 35uA; stop and restart both parity and compton runs;
    17:50 zero Hall C asymmetry during run 2566, new IA point 1.565
    21:49 lost lock for Right arm Q2 and Q3, reset IOC, see 127559
    22:52 Right arm magnets recovered;
    23:15 Found we lost IOC for both septa, see 127561; it must have happened when we reset the right magnets IOC. Too bad we didn't notice it until now. => reset septa IOC => need to reset from downstairs => tech on call is coming in;
    23:30 Hall in controlled access;
    
    Accumulated charge of this shift: 0.498 C (two arms)
    
    run summary:
    
    run#  IHWP  start  stop  comment
    2564   IN   16:03 16:29   Junk, harp scan during the last 10 minutes of run
    2565   IN   16:34 16:51   Production, 26 uA, 32K events, ended for spot move
    2566   IN   17:09 18:05   Production, 34 uA
    2567   IN   18:06 19:01   Production, 34 uA
     
    2568   OUT  19:06 20:03   Production, 35 uA
    2569   OUT  20:03 20:59   Production, 35 uA
    2570   OUT  20:59 21:19   Production, 35 uA, kcoda at the end to fix the feedback redbox alarm
    2571    junk, right arm magnet problem, no septum
    2572    junk, no septum