    User name X. Zheng

    Log entry time 00:32:00 on July 2,2004

    Entry number 127706

    keyword=shift summary

    16:06 target is in position => start data taking, first did a profile scan, run# 2585 and 2586;
    16:28 At the end of #2585, kcoda to clear the feedback red alarm;
    18:43 change IHWP to IN after #2588; Kent tried to reboot DAQ;
    
     see ;
    
    19:06 Preparing for dithering test;
    19:57 Both septa strip charts flattened since ~18:00
     Reboot Septum control, see 127646;  Meanwhile reboot DAQ IOC again, see 127659
    
    21:20 Septa control recovered, start dithering test. See 127704 for details.
    
    23:17 Most of target script charts flattened, reboot IOC;
    
    accumulated charge of this shift (production): 0.12 C (two arms)
    
    
    run summary
    
    run#  IHWP   start   stop    comment
    2585  OUT    16:11   16:29   profile scan, beam was off for a little while during the scan; kcoda at the end of run
    2586  OUT    16:31   16:43   profile scan;
    
    2587  OUT    16:44   17:43   35 uA production;
    2588  OUT    17:46   18:41   35 uA production, Septa flatlined during this run; detector signals do not look good, but Lumi data are okay;
    
    2589  IN     18:46   19:09   35 uA production, Septa flatlined;
    2590-2593 nbsp;IN     junk, Septa flatlined;
    2594-26xx test runs;