NEXT
User name a-onl
Log entry time 19:04:06 on July 12, 2004
Entry number 128392
keyword=End_of_Run_1239
****************************
Run Number: 1239
End of Run Comment:
Run_type=other,beam_energy=3.0289,beam_halfwaveplate=in,beam_raster=on,comment_text=raster check,daq_mode=TWOARM,kin_name=,leftarm_p=2.971,leftarm_theta=6,rightarm_p=2.960,rightarm_theta=6,target_type=Hydrogen
raster size is 3*3.5 mm
PRESCALE FACTORS:ps1=600 ps2=467 ps3=533 ps4=400 ps5=65535 ps6=65535 ps7=65535 ps8=4
EVENTS[0]: 41435 [+]: 41435 [-]: 0
TIME [0]: 2.698 mins [+]: 3.012 mins [-]: 0.017 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 100.00% [+]: 89.56% [-]: 100.00%
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.0 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/2.3 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] : 0.0/0.0 Hz T8[0] :256.0/1024.0 Hz
T1[+] : 0.0/0.0 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/2.3 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] : 0.0/0.0 Hz T8[+] :256.0/1024.0 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/0 T2[0] : 0/0 T3[0] : 0/372 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 0/0 T8[0] : 41437/165749
T1[+] : 0/0 T2[+] : 0/0 T3[+] : 0/411 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 0/0 T8[+] : 46263/185055
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 19.9254uA BCM x3 : -0.0215uA BCM x10: 19.8463uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.011E+06 ppm BCM u3 : 1E+39 ppm BCM u10:1.003E+06 ppm
BCM d1 :1.003E+06 ppm BCM d3 : 1E+39 ppm BCM d10:1.002E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.003259 BCM u3 [0]:-4.373E-06 BCM u10[0]:0.003243
BCM u1 [+]:0.003767 BCM u3 [+]:-4.883E-06 BCM u10[+]:0.003749
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.003191 BCM d3 [0]:-2.573E-06 BCM d10[0]:0.003182
BCM d1 [+]:0.003688 BCM d3 [+]:-2.873E-06 BCM d10[+]:0.003677
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 1239 at Mon Jul 12 19:03:55 EDT 2004
Left Arm D1 momentum : 2.97099
Left Arm arm angle : 12.321
Right Arm D1 momentum : 2.96
Right Arm arm angle : 0
HALLA:p : 3028.91
HALLA:dpp : -1.61326e-05
Tiefenbach Hall A energy : 3028.91
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.634766
Left septum set current : 275.5
Left septum current readback : 275.25
Left septum upper coil T : 6.55
Left septum lower coil T : 6.85
Left septum yoke T : 5
Left septum bore shield T : 80.35
Left Arm Q1 momentum : 2.97086
Left Arm Q2 power supply current : 1289.36
Left Arm Q2 momentum : 2.97122
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1040.98
Left Arm D1 momentum : 2.97099
Left Arm D1 NMR : 1.10008
Left Arm Q3 power supply current : 1391.35
Left Arm Q3 momentum : 2.97113
Left Arm Q3 power supply polarity : disabled
Right septum set current : 275.35
Right septum current readback : 274.25
Right septum upper coil T : 7.05
Right septum lower coil T : 6.75
Right septum yoke T : 5.75
Right septum bore shield T : 73.15
Right Arm Q1 momentum : 2.9601
Right Arm Q1 gauss meter : -0.04375
Right Arm Q2 power supply current : 1284.27
Right Arm Q2 momentum : 2.95949
Right Arm Q2 gauss meter : 0.6745
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1061.9
Right Arm D1 momentum : 2.96
Right Arm D1 NMR : 1.09842
Right Arm Q3 power supply current : 1386.04
Right Arm Q3 momentum : 2.95978
Right Arm Q3 gauss meter : 0.6218
Right Arm Q3 power supply polarity : disabled
RICH Vmon 16 : 0
RICH Imon 16 : 0
RICH Vmon 17 : 0
RICH Imon 17 : 0
RICH Radiator Oxygen : -1.07422
RICH Radiator Moisture : -1.07422
RICH Radiator Pressure : 0.632324
RICH Condensor temperature : 18.8945
RICH Gas Oxygen : -0.976562
RICH Gas Moisture : -1.07422
RICH Argon Flow : 4.98047
RICH Methane Flow : 0.878906
RICH A Volts : 0.362305
RICH B Volts : 0.197754