• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Moffit

    Log entry time 04:56:49 on July17,2004

    Entry number 128735

    keyword=192 switch power cycled

    Paged because of loss of communication with ROCs in the Left and Right arm (ROC25 and 26). Determined that the 192 switch was down and required a power cycle (pings to 129.57.192.2, ahut1, ahut2 all failed).

    During a quick controlled access, power cycled the 192 network switch by unplugging the power cable and plugging it back in. Had Al, upstairs, reboot those ROCS..

    ROC in Left Arm forgot its NVRAM, and could not boot. Used the ROC in the Right Arm as a template to recover... and it booted up just fine.

    Ryan Snyder accompanied me down to the hall to see what the procedure was.. and should be able to do this without Bob or I needing to come in. However, I should still be paged before making an access (sometimes the 192 switch IS NOT the problem).