NEXT
User name J. Singh
Log entry time 08:33:01 on July23,2004
Entry number 129383
keyword=owl shift summary
♦ owl shift summary - 07/23/04 ♦
Did septum scan until CHL trip. see halogs 129359 and 129367
2311:0006 run 3068, 100k, IHWP = IN, production in right arm while ramping up left arm
0009:0013 run 3069, junk
0015:0025 run 3070, 20k, IHWP = IN, background study , left = 3.160 GeV (+6.4%)
0025:0058 setting left HRS = 2.9710 GeV & septum read (set) = 192.75 A (193.00 A)
0028:0058 run 3071, 53k, IHWP = IN, production in right arm while setting left arm
0100:0110 run 3072, 18k, IHWP = IN, septum scan -29.9% (2.0820 GeV)
0110:0126 setting septum read (set) = 233.75 A (234.00 A)
0127:0137 run 3073, 18k, IHWP = IN, septum scan -15.0% (2.5248 GeV)
0137:0149 setting septum read (set) = 253.25 A (253.50 A)
0149:0158 run 3074, 17k, IHWP = IN, septum scan -7.9% (2.7355 GeV)
0158:0205 setting septum read (set) = 264.00 A (264.50 A)
0200 bleedthrough = 0.77%, halog 129347
0205:0215 run 3075, 18k, IHWP = IN, septum scan -4.0% (2.8516 GeV)
0215:0223 setting septum read (set) = 275.25 A (275.50 A)
0223:0229 run 3076, 12k, IHWP = IN, septum scan +0.1% (2.9731 GeV)
0229:0306 setting septum read (set) = 316.75 A (317.00 A)
0232:0305 run 3077, 60k, IHWP = IN, production in right arm while setting left arm
0306:0316 run 3078, 18k, IHWP = IN, septum scan +15.2% (3.4214 GeV)
0316:0412 setting septum set = 358A, reached read = 342 A.
0322:0412 run 3079, 89k, IHWP = IN, production in right arm while setting left arm, target HPH prproblem at about 50k for about 3k (halog 129356, end of run is septum scan ~+24% (~3.6833 GeV)
0434:0705 run 3080, pedestal run
0408:0800 At 0408, the CHL tripped. It was due to some power supply failure of a CAMAC for a cold compressor. At about 0630 out target started warming up due to a loss of CHL flow.
We talked to Dave Meekins and he said that there is nothing that we can do but to close the JT valve. At 0640, discussions started about whether we would be amenable to doing a spot change.
At the end of the shift, the target temp is 95K+.
see halogs 129358, 129361, 129363, 129364