• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name J. Singh

    Log entry time 07:59:27 on July24,2004

    Entry number 129531

    keyword=TECHS: losing cryolevels in magnets

    At 0743, we noticed that the right septum LHe level starting dropping. A few min later, we noticed that we had lost LQ1, LDip, and RQ1 due to drops in magnet cryolevels.

    We asked for no beam and the MCC contact the cryo people.

    fig 1: hall A tools
    fig 2: right septum trip

    At 0757, we decided to ramp the septa down to 0A before they quench. We are on our way to losing the other HRS magnets...




    FIGURE 1

    FIGURE 2