    User name A. Camsonne

    Log entry time 23:17:47 on October 3,2004

    Entry number 132856

    Followups:

    keyword=ROC17 and T5 rate change and scalers at 2.5uA

    By looking at the rate I save that T5 rate went down from 50 to 30 Hz.
    It looks like the ROC17 which holds the calorimeter trigger got corrupted which raised the threshold by one unit ( so 4 for a tower meaning that threshold might have gone to 61 instead of 57 )
    Rebooting the ROC17 solved the problem. Run going from 3062 to 3075 are affected. Rates of T5 should be of the order of 50 Hz


    FIGURE 1