Main INDEX
Monthly INDEX
PREV
NEXT
User name Eric Voutier
Log entry time 14:51:29 on November 7,2004
Entry number 136061
Followups:
keyword=Tagger A16 / Control Acc.
Went to control access to troubleshoot the problem of small signal
in A16...
After several checks, identify that the amplifier is dead. The change
requires to dismount the tagger and bringing it back to the table in
an horizontal position, remove the cover, and change the amplifier
stage of the PMT basis.
This is a 2-3 hours work that should be scheduled during the next
beam studies.