• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name mazouz

    Log entry time 00:08:34 on November 8,2004

    Entry number 136113

    keyword=Shift summary

    Shift summary:
    --------------
    16:00 - 19:00 : Check tagger signals in the hall (see E. Voutier
    entry in the halog)

    19:00 - 21:00 : Mux Veto Tests. (see A. Camsonne entry)

    21:00 - 00:00 : Taking data.


    Run list:
    ----------
    run 4454 : nDVCS Pedestal run (10k)
    run 4456 : nDVCS (50k) no signal for A18 A24 and B26. Tagger HV
    adjusted to have 60 mV. I=2.5 uA.
    run 4457 : nDVCS (63k). Signals in all Paddles. Good run.
    run 4458 : Test Mux veto.
    run 4459 : nDVCS (?). ? (19:03 - 19:30)
    run 4460 : nDVCS (177k). Good run.
    runs 4461 - 4466 : Test Mux Veto
    run 4467 : nDVCS (100k). Good run. I=2 uA DT=40%
    run 4468 : DVCS Mux Veto (100k). Good run. I=2 uA DT=20%
    run 4469 : DVCS Mux Veto (100k). Good run. I=3 uA DT=30% (High DC
    current for some paddles (0.72V for A6 and 0.65V for A9
    for example)
    run 4470 : DVCS Mux Veto (150k). Good run.
    run 4471 : DVCS Mux Veto (150k). Good run.
    run 4472 : DVCS Mux Veto (100k). Good run.
    run 4473 : DVCS Mux Veto (100k). Good run.
    run 4474 : DVCS Mux Veto (100k). Good run.