Main INDEX
Monthly INDEX
PREV
NEXT
User name dhayes
Log entry time 00:07:21 on November24,2004
Entry number 137482
keyword=shift summary
16:00 - 17:00 11 beam trips, subtracted 4 minutes from abu
17:00 - 18:00 13 beam trips, subtracted 4 minutes from abu
18:00 - 19:00 bpm tests, no way to count beam trips
19:00 - 20:00 bpm tests, no way to count beam trips
20:00 - 21:00 11 beam trips, subtracted 4 minutes from abu
21:00 - 22:00 12 beam trips, subtracted 4 minutes from abu
22:00 - 23:00 13 beam trips, subtracted 4 minutes from abu
18:15 bleed thru is 0.63%
18:21 stopped run 4959 to reboot IOC for target problem.
18:32 stopped run 4960 to do bpm calibration
runs 4961 to 4967 bpm calibration on optics target
19:22 finished bpm calibration, return to production mode
entered wrong target type for run 4968, it was LD2 not optics.
22:24 bleed thru is 0.46%