Main INDEX
Monthly INDEX
PREV
NEXT
User name P. Monaghan
Log entry time 08:05:27 on January10,2005
Entry number 138823
keyword=Run Summary for owl shift
Kinematic A1 :- p = 1.1374 GeV/c; L-HRS = 17.0 degrees
Run # Details
1633 00:29 - 00:41 LH2 4cm; 250K; ps3 = 300; ps6 = 800
1634 00:41 - 00.53 LH2 4cm; 250K; ps3 = 300; ps6 = 800 (continued with data taking for same kinematic as Ran was working on the analyzer)
--------------------------------------------------------------------
Insert SIEVE - kinematic A1
1635 JUNK - Resetting prescale factors
1636 01:13 - 01:27 LH2 4cm; 250K; ps3 = 5; ps6 = 900; Sieve IN
Change to tilted carbon target; sieve in, kinematic A1.
1637 01:35 - 01:54 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; Sieve IN
--------------------------------------------------------------------
01:55 - Left HRS bogie control problems.
03:20 - Bogie problem fixed and configuration changed to kinematic A2.
--------------------------------------------------------------------
Kinematic A2 :- p = 1.1149 GeV/c; L-HRS = 20.0 degrees.
1638 03:29 - 04:00 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; Sieve IN
Move to 4cm liquid hydrogen target.
1639 04:06 - 04:20 LH2 4cm; 250K; ps3 = 2; ps6 = 1000; Sieve IN
--------------------------------------------------------------------
04:20 Configuration change to kinematic A3.
--------------------------------------------------------------------
Kinematic A3 :- p = 1.0986 GeV/c; L-HRS = 23.0 degrees.
1640 JUNK - MCC lost a power supply
1641 05:12 - 05:28 LH2 4cm; 250K; ps3 = 1; ps6 = 900; sieve IN
Move to tilted 12C target.
1642 05:35 - 06:21 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; sieve IN
Remove sieve slit.
1643 06:27 - 06:44 Tilted 12C; 250K; ps3 = 10; ps6 = 2000.
Move to LH2 4cm target.