• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name P. Monaghan

    Log entry time 08:05:27 on January10,2005

    Entry number 138823

    keyword=Run Summary for owl shift

    Kinematic A1 :- p = 1.1374 GeV/c; L-HRS = 17.0 degrees

    Run # Details

    1633 00:29 - 00:41 LH2 4cm; 250K; ps3 = 300; ps6 = 800
    1634 00:41 - 00.53 LH2 4cm; 250K; ps3 = 300; ps6 = 800 (continued with data taking for same kinematic as Ran was working on the analyzer)

    --------------------------------------------------------------------
    Insert SIEVE - kinematic A1

    1635 JUNK - Resetting prescale factors
    1636 01:13 - 01:27 LH2 4cm; 250K; ps3 = 5; ps6 = 900; Sieve IN

    Change to tilted carbon target; sieve in, kinematic A1.

    1637 01:35 - 01:54 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; Sieve IN

    --------------------------------------------------------------------
    01:55 - Left HRS bogie control problems.

    03:20 - Bogie problem fixed and configuration changed to kinematic A2.

    --------------------------------------------------------------------
    Kinematic A2 :- p = 1.1149 GeV/c; L-HRS = 20.0 degrees.

    1638 03:29 - 04:00 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; Sieve IN

    Move to 4cm liquid hydrogen target.

    1639 04:06 - 04:20 LH2 4cm; 250K; ps3 = 2; ps6 = 1000; Sieve IN

    --------------------------------------------------------------------
    04:20 Configuration change to kinematic A3.

    --------------------------------------------------------------------
    Kinematic A3 :- p = 1.0986 GeV/c; L-HRS = 23.0 degrees.

    1640 JUNK - MCC lost a power supply
    1641 05:12 - 05:28 LH2 4cm; 250K; ps3 = 1; ps6 = 900; sieve IN

    Move to tilted 12C target.

    1642 05:35 - 06:21 Tilted 12C; 250K; ps3 = 1; ps6 = 2000; sieve IN

    Remove sieve slit.

    1643 06:27 - 06:44 Tilted 12C; 250K; ps3 = 10; ps6 = 2000.

    Move to LH2 4cm target.