• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:34:52 on January 25, 2005

    Entry number 140043

    keyword=Start_Run_2087,Run_type=SRC,bbarm_theta=99,beam_energy=4.6,beam_raster=on,comment_text=production run 5 microA,daq_mode=SRCEXPT,kin_name=E1,leftarm_p=3.762,leftarm_theta=19.5,ndarm_distance=6,ndarm_theta=98,rightarm_p=1.45,rightarm_theta=40.1,target_type=LD2 15cm
    Beginning-of-run EPICS data for Run Number 2087 at Tue Jan 25 23:34:32 EST 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = L.and.R coinc
    ; T6 = BB single trigger  (Set to 65536 or larger to disable)
    ; T7 = ND single trigger  (Set to 65536 or larger to disable)
    ; below was for LD2 at 10uA 
    ;ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps6=13500,ps7=99999,ps8=99999
    
    
    ps1=175,ps2=12,ps3=30,ps4=46,ps5=1,ps6=10,ps7=99999,ps8=99999
    
    
    
    Left Arm Q1 momentum : 3.76216
    Left Arm Q1 power supply : 2830.33
    Left Arm Q1 gauss meter : -0.23878
    Left Arm Q2 power supply current : 1619.87
    Left Arm Q2 momentum : 3.76189
    Left Arm Q2 gauss meter : 0.8519
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1379.4
    Left Arm D1 momentum : 3.76201
    Left Arm D1 NMR : 1.3936
    Left Arm Q3 power supply current : 1497.78
    Left Arm Q3 momentum : 3.76214
    Left Arm Q3 gauss meter : -0.7493
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 1.44999
    Right Arm Q1 power supply : 1090.3
    Right Arm Q1 gauss meter : 0.027239
    Right Arm Q2 power supply current : 624.119
    Right Arm Q2 momentum : 1.4502
    Right Arm Q2 gauss meter : -0.3286
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 499.088
    Right Arm D1 momentum : 1.45
    Right Arm D1 NMR : 0.538077
    Right Arm Q3 power supply current : 576.846
    Right Arm Q3 momentum : 1.4497
    Right Arm Q3 gauss meter : -0.2591
    Right Arm Q3 power supply polarity : enabled
    BigBite magnet magnet probe : 0.9323
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 0
    Left Arm Top VDC Current : 4.00391
    Left Arm Bottom VDC Current : 3.66211
    Left Arm Top VDC voltage : 4.00928
    Left Arm Bottom VDC voltage : 3.99902
    Right Arm Top VDC voltage : 4.00049
    Right Arm Bottom VDC voltage : 3.9917
    Average current of the two cavities : 4.94692
    Current on Unser monitor : -3.52556
    Current on Upstream bcm : 4.90076
    Current on Downstream bcm : 4.99308
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 43.7687
    Tiefenbach Hall A energy : 4627.51
    Tiefenbach Hall C energy : 2347.05
    Delta(E)/E width (MV_AI_DXWID) : 4.92803
    HALLA:p : 4627.51
    HALLA:dpp : -4.43852e-06
    MBSY1c Hall A Beam energy : 4637.02
    MBSY3c Hall C Beam energy : 2351.94
    MBSY1c magnet current (amp) : 193.436
    MBSY1c Bdl : 1.15717e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.111816
    HacL_HPE1313A:0_Ch55 : 23.9746
    HacL_HPE1313A:0_Ch54 : -0.103516
    Left Arm Angle Floor Angle : HacL_AglMrk --- Invalid channel name
    Left Arm Angle Vernier : HacL_AglVrn --- Invalid channel name
    Left Arm Scattering Angle : HacL_alignAGL --- Invalid channel name
    Right Arm Angle Floor Angle : 40
    Right Arm Angle Vernier : -17
    Right Arm Scattering Angle : 40.099
    IPM1C12.XPOS : 0.00741151
    IPM1C12.YPOS : 0.127249
    IPM1H04A.XPOS : -0.0545893
    IPM1H04A.YPOS : 0.0977075
    IPM1H04B.XPOS : -0.0718881
    IPM1H04B.YPOS : -0.0282439
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -50.2088
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 33.42
    Laser attenuation Hall A : 95
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    Target : D2 15cm
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 60
    Encoder position : 3.14261e+07
    temperature loop 1 : 22
    temperature loop 1 : 22.02
    temperature loop 1 : 28.52
    temperature loop 2 : 19
    temperature loop 2 : 22.43
    temperature loop 2 : 19.08
    pressure loop D2 : 24.7242
    pressure loop H2 : 21.5335