• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Higinbotham

    Log entry time 06:09:48 on January 28, 2005

    Entry number 140202

    This entry is a followup to: 140178

    keyword=Wien Angle

    -50 was the best that could be achieved quickly [i.e. without a retune of the injector] Before it was changed a couple of days ago, the Wien angle was at 0 which would have been completley wrong. As the source is group is reporting an 85% polarization, we should have 70% long. polarization. [.85*cos(35)=0.70] in the Hall.