    Log entry time 14:10:51 on January 31, 2005

    Entry number 140412

    This entry is a followup to: 140224

    keyword=HV changes - list of changes

    After the last swap of HV crates, few of the channels had been restored to wrong values ( this was appereant when looking on both the scaler and ADCs/TDCs) . a full post-updated list exists on file

    the changes which where done after the swap appear in this list = first line - the old value second line - the updated value

    N1-1R 12 0 0 -1505 N1-2R 12 0 1 -1570

    N1-1L 12 7 11 -1570 N1-1L 12 7 11 -1550

    N1-5L 13 4 4 -1540 N1-5L 13 4 4 -1500

    N1-6L 13 4 5 -1730 N1-6L 13 4 5 -1700

    N1-14L 13 5 1 -1990 N1-14L 13 5 1 -2160

    N1-25L 13 6 0 -1420 N1-25L 13 6 0 -1450

    N1-28L 13 6 3 -1500 N1-28L 13 6 3 -1570

    N1-29L 13 6 4 -1405 N1-29L 13 6 4 -1380

    N1-30L 13 6 5 -1470 N1-30L 13 6 5 -1490

    N2-2R 12 2 7 -1900 N2-2R 12 2 7 -1950

    N2-15R 12 3 8 -1685 N2-15R 12 3 8 -1740

    N2-16R 12 3 9 -2085 N2-16R 12 3 9 -2105

    N2-19L 13 0 0 -2015 N2-19L 13 0 0 -2000

    N3-13R 13 10 6 -1960 N3-13R 13 10 6 -2000

    N3-14R 13 10 7 -2070 N3-14R 13 10 7 -2140

    N3-21L 13 2 2 -1450 N3-21L 13 2 2 -1470

    V-21R 12 9 8 -1090 V-21R 12 9 8 -1160