• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:26:27 on February 2, 2005

    Entry number 140609

    keyword=Start_Run_2296,Run_type=other,bbarm_theta=99,beam_energy=4.627,beam_raster=on,comment_text=GEn N-20, LH2 15 cm, 20microAmp,daq_mode=proton,kin_name=F1,leftarm_p=2.450,leftarm_theta=27.50,ndarm_distance=15,ndarm_theta=40,rightarm_p=1.00,rightarm_theta=15.0,target_type=LH2 15cm
    Beginning-of-run EPICS data for Run Number 2296 at Wed Feb 2 09:26:19 EST 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = L.and.R coinc
    ; T6 = BB single trigger  (Set to 65536 or larger to disable)
    ; T7 = ND single trigger  (Set to 65536 or larger to disable)
    ; below was for LD2 at 10uA 
    ;ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps6=13500,ps7=99999,ps8=99999
    
    
    ps1=99999,ps2=99999,ps3=1,ps4=10,ps5=1,ps6=99999,ps7=30000,ps8=65535
    
    
    Left Arm Q1 momentum : 2.45001
    Left Arm Q1 power supply : 1843.22
    Left Arm Q1 gauss meter : 0.15627
    Left Arm Q2 power supply current : 1054.84
    Left Arm Q2 momentum : 2.44971
    Left Arm Q2 gauss meter : -0.5553
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 843.607
    Left Arm D1 momentum : 2.45
    Left Arm D1 NMR : 0.906756
    Left Arm Q3 power supply current : 975.402
    Left Arm Q3 momentum : 2.45003
    Left Arm Q3 gauss meter : 0.4882
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.00011
    Right Arm Q1 power supply : 752.018
    Right Arm Q1 gauss meter : 0.018823
    Right Arm Q2 power supply current : 430.334
    Right Arm Q2 momentum : 0.999922
    Right Arm Q2 gauss meter : -0.22634
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 344.142
    Right Arm D1 momentum : 0.999999
    Right Arm D1 NMR : 0.371088
    Right Arm Q3 power supply current : 398.004
    Right Arm Q3 momentum : 1.00024
    Right Arm Q3 gauss meter : -0.17809
    Right Arm Q3 power supply polarity : enabled
    BigBite magnet magnet probe : 9323
    BigBite magnet current setpoint : 518
    BigBite magnet current readback : 0
    Left Arm Top VDC Current : 1.31836
    Left Arm Bottom VDC Current : -1.36719
    Left Arm Top VDC voltage : 3.99609
    Left Arm Bottom VDC voltage : 4.00146
    Right Arm Top VDC voltage : 4.00244
    Right Arm Bottom VDC voltage : 3.99805
    Average current of the two cavities : 19.6847
    Current on Unser monitor : 10.3302
    Current on Upstream bcm : 19.2771
    Current on Downstream bcm : 20.0922
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 19.8217
    Tiefenbach Hall A energy : 4626.64
    Tiefenbach Hall C energy : 2346.35
    Delta(E)/E width (MV_AI_DXWID) : 0
    HALLA:p : 4626.56
    HALLA:dpp : -0.00020934
    MBSY1c Hall A Beam energy : 4637.02
    MBSY3c Hall C Beam energy : 2351.94
    MBSY1c magnet current (amp) : 193.436
    MBSY1c Bdl : 1.15717e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.620166
    HacL_HPE1313A:0_Ch58 : -0.137695
    HacL_HPE1313A:0_Ch55 : 23.9746
    HacL_HPE1313A:0_Ch54 : -0.319824
    Left Arm Angle Floor Angle : 27.5
    Left Arm Angle Vernier : 31.1
    Left Arm Scattering Angle : 27.5002
    Right Arm Angle Floor Angle : 15
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 14.9999
    IPM1C12.XPOS : 0.817914
    IPM1C12.YPOS : 0.144336
    IPM1H04A.XPOS : 0.0320705
    IPM1H04A.YPOS : 0.660751
    IPM1H04B.XPOS : 0.0681971
    IPM1H04B.YPOS : 0.19631
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 158
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : IN
    Target : H2 15cm
    fan frequency loop 1 : 24
    fan frequency loop 2 : 24
    Encoder position : 2.42735e+07
    temperature loop 1 : 119.99
    temperature loop 1 : 22
    temperature loop 1 : 28.58
    temperature loop 2 : 19
    temperature loop 2 : 42.84
    temperature loop 2 : 19.2
    pressure loop D2 : 23.8148
    pressure loop H2 : 21.5076