User name apar
Log entry time 15:39:51 on May 28, 2005
Entry number 144795
keyword=End_of_Parity_Run_3412__CODA_Config=Beamline
End-of-Parity-run EPICS data for Run Number 3412 at Sat May 28 15:39:46 EDT 2005
CODA Configuration: Beamline
# Timing board information: # Integrate Time = 32.50 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 83.2403
Wien BDL : 3.18799
Wien field : 55.48
Laser attenuation Hall A : 82
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 5
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 1.04
Gun2: PC (PITA) NEG : 1.392
Gun3: PC (PITA) POS : 2.08845
Gun3: PC (PITA) NEG : 2.72727
Pockels Cell Voltage POS : 2.79609
Pockels Cell Voltage NEG : 2.67399
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
LUMI HV - Ch 0 : -3.4
LUMI HV - Ch 1 : -4.6
LUMI HV - Ch 2 : -2.4
LUMI HV - Ch 3 : -3.3
LUMI HV - Ch 4 : -2.9
LUMI HV - Ch 5 : -3.1
LUMI HV - Ch 6 : -3.3
LUMI HV - Ch 7 : -2.9
LUMI HV - Ch 8 : -18.7
LUMI HV - Ch 9 : -19.4
LUMI HV - Ch 10 : -19
LUMI HV - Ch 11 : -13.1
HAPPEX Detector1 HV - Left Slot10 Ch9 : -23.6
HAPPEX Detector2 HV - Left Slot10 Ch10 : -19.7
HAPPEX Detector3 HV - RightB Slot10 Ch10 : -22.6
HAPPEX Detector4 HV - RightB Slot10 Ch9 : -20.6
Scanner Left HV - Left Slot10 Ch11 : -21
Scanner Right HV - RightB Slot10 Ch11 : -19.6
Left Arm arm angle : 12.5003
Right Arm arm angle : 12.4999
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.000162
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.262
Left Arm Q2 momentum : 0.000603756
Left Arm Q2 gauss meter : 0.0008819
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 0.0591471
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.21242
Left Arm Q3 power supply current : 2.05633
Left Arm Q3 momentum : 0.00439116
Left Arm Q3 gauss meter : 9.67e-05
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.51e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.276904
Right Arm Q2 momentum : 0.000638101
Right Arm Q2 gauss meter : -0.0010727
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1.65715
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.18027
Right Arm Q3 power supply current : 0.196048
Right Arm Q3 momentum : 0.000418647
Right Arm Q3 gauss meter : -0.00047
Right Arm Q3 power supply polarity : enabled
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 0.78125
Right Arm Top VDC Current : -0.537109
Right Arm Bottom VDC Current : 2.05078
Left Arm Top VDC voltage : 0.0102539
Left Arm Bottom VDC voltage : 0.0107422
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 4
Average current of the two cavities : 0.0278448
Current on Unser monitor : 25.4067
Current on Upstream bcm : 0.0278679
Current on Downstream bcm : 0.0278217
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.13221
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 4637
MBSY3c Hall C Beam energy : 5787.59
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 1.15717e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0578125
Left LVDT HPM : 0.3501
Left LVDT VPM : 3695
HacL_HPE1313A:0_Ch58 : -0.187012
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.0551758
HacL_alignROLL : 0.394295
HacL_alignPITCH : -0.0974733
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 12.5003
Right Arm Collimator : -0.000537109
Right LVDT HPM : 3282
Right LVDT VPM : 3842
HacR_HPE1313A:0_Ch58 : -0.563477
HacR_HPE1313A:0_Ch55 : 20.459
HacR_HPE1313A:0_Ch54 : -0.932129
HacR_alignROLL : -0.454904
HacR_alignPITCH : 0.00881398
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
Arc OTR x-position : -2.06095
Arc OTR y-position : -1.2265
Arc OTR x-width : 2.97311
Arc OTR y-width : 1.97542
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Target StepMotor Position : 254208
Target Pump Speed : 2048