• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:08:15 on June 6, 2005

    Entry number 145309

    keyword=Start_Run_4353,Run_type=other,beam_energy=1.85,beam_raster=off,comment_text=tantalum delta=0, 5uA,daq_mode=twoarm,kin_name=,leftarm_p=1.85,leftarm_theta=6.0,rightarm_p=1.85,rightarm_theta=6.0,target_type=Tantulum
    Beginning-of-run EPICS data for Run Number 4353 at Mon Jun 6 12:08:12 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    
    ps1=3,ps2=100,ps3=3,ps4=100,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    
    Left septum set current : 171.27
    Left septum current readback : 167.847
    Left septum upper coil T : 6.216
    Left septum lower coil T : 6.205
    Right septum set current : 174.3
    Right septum current readback : 172.241
    Right septum upper coil T : 6.952
    Right septum lower coil T : 6.293
    Left Arm Q1 momentum : 1.84998
    Left Arm Q1 power supply : 1110.91
    Left Arm Q1 gauss meter : -0.09388
    Left Arm Q2 power supply current : 802.764
    Left Arm Q2 momentum : 1.8499
    Left Arm Q2 gauss meter : 0.4232
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 625.021
    Left Arm D1 momentum : 1.85
    Left Arm D1 NMR : 0.684598
    Left Arm Q3 power supply current : 866.322
    Left Arm Q3 momentum : 1.84997
    Left Arm Q3 gauss meter : -0.4333
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 1.85005
    Right Arm Q1 power supply : 1105.94
    Right Arm Q1 gauss meter : -0.02764
    Right Arm Q2 power supply current : 802.87
    Right Arm Q2 momentum : 1.85014
    Right Arm Q2 gauss meter : 0.422
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 639.652
    Right Arm D1 momentum : 1.85
    Right Arm D1 NMR : 0.686512
    Right Arm Q3 power supply current : 866.349
    Right Arm Q3 momentum : 1.85003
    Right Arm Q3 gauss meter : 0.3889
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 4.19922
    Left Arm Bottom VDC Current : 0.634766
    Left Arm Top VDC voltage : 3.98779
    Left Arm Bottom VDC voltage : 4
    Right Arm Top VDC voltage : 4.00195
    Right Arm Bottom VDC voltage : 3.99023
    Average current of the two cavities : 3.71629
    Current on Unser monitor : 29.6093
    Current on Upstream bcm : 3.79624
    Current on Downstream bcm : 3.63635
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 5.17252
    Tiefenbach Hall A energy : 1852.25
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 0
    HALLA:p : 1852.25
    HALLA:dpp : -4.79537e-06
    MBSY1c Hall A Beam energy : 1854.24
    MBSY3c Hall C Beam energy : 1856.46
    MBSY1c magnet current (amp) : 77.1102
    MBSY1c Bdl : 462728
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0579102
    HacL_HPE1313A:0_Ch58 : -0.185059
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : 0.050293
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : -0.0686985
    IPM1C12.YPOS : 0.0141188
    IPM1H04A.XPOS : 1.4704
    IPM1H04A.YPOS : 1.10709
    IPM1H04B.XPOS : -0.215256
    IPM1H04B.YPOS : -0.622848
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 73
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : Yes
    SLI horiz size mm : 0.187718
    SLI Energy spread *10^5 : 4.69295
    SLI x position : 1.3118
    SLI vert. size mm : 0.246334
    SLI y position : 1.38967
    Waterfall Pump Speed : 3175
    Target StepMot Pos. : 1.21728e+06