    User name a-onl

    Log entry time 23:24:58 on June 9, 2005

    Entry number 145684

    keyword=Start_Run_4464,Run_type=cosmics,beam_energy=3.65,beam_raster=off,comment_text=detectot tests,daq_mode=twoarm,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=thick 12C target
    Beginning-of-run EPICS data for Run Number 4464 at Thu Jun 9 23:24:55 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    ps1=100000,ps2=1,ps3=100000,ps4=1,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    
    
    Left septum set current : 184.672
    Left septum current readback : 181.274
    Left septum upper coil T : 6.26
    Left septum lower coil T : 6.241
    Right septum set current : 133.445
    Right septum current readback : 131.348
    Right septum upper coil T : 7.341
    Right septum lower coil T : 6.559
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10009
    Left Arm Q2 power supply current : 850.499
    Left Arm Q2 momentum : 1.9599
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.106
    Left Arm D1 momentum : 1.96003
    Left Arm D1 NMR : 0.725288
    Left Arm Q3 power supply current : 917.819
    Left Arm Q3 momentum : 1.95994
    Left Arm Q3 gauss meter : 0.4594
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44123
    Right Arm Q1 power supply : 861.555
    Right Arm Q1 gauss meter : -0.02159
    Right Arm Q2 power supply current : 625.652
    Right Arm Q2 momentum : 1.44176
    Right Arm Q2 gauss meter : 0.3279
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 493.747
    Right Arm D1 momentum : 1.4414
    Right Arm D1 NMR : 0.534885
    Right Arm Q3 power supply current : 674.968
    Right Arm Q3 momentum : 1.44135
    Right Arm Q3 gauss meter : 0.303
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : 4.05273
    Left Arm Top VDC voltage : 4.00146
    Left Arm Bottom VDC voltage : 4.00049
    Right Arm Top VDC voltage : 4.00586
    Right Arm Bottom VDC voltage : 3.99463
    Average current of the two cavities : 0.0268771
    Current on Unser monitor : -10.9069
    Current on Upstream bcm : 0.029615
    Current on Downstream bcm : 0.0241391
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143517
    Tiefenbach Hall A energy : 3654.59
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 7.29618
    HALLA:p : 3654.59
    HALLA:dpp : 0
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1856.46
    MBSY1c magnet current (amp) : 5.08079e-06
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0576172
    HacL_HPE1313A:0_Ch58 : -0.186035
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : 0.050293
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : 0.00465462
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 65
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.26708
    SLI vert. size mm : 0
    SLI y position : 0.706103
    Waterfall Pump Speed : 3658
    Target StepMot Pos. : 3.14342e+06