User name a-onl
Log entry time 22:27:17 on June 10, 2005
Entry number 145787
keyword=Start_Run_4500,Run_type=production,beam_energy=3.65,beam_raster=off,comment_text=TEST RUN,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4500 at Fri Jun 10 22:27:14 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
;ps1=3500,ps2=650,ps3=800,ps4=400,ps5=30,ps6=150,ps7=1,ps8=65535
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps6=1,ps7=1,ps8=65535
Left septum set current : 184.672
Left septum current readback : 181.763
Left septum upper coil T : 6.243
Left septum lower coil T : 6.221
Right septum set current : 133.445
Right septum current readback : 130.737
Right septum upper coil T : 6.832
Right septum lower coil T : 6.098
Left Arm Q1 momentum : 1.95991
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.10007
Left Arm Q2 power supply current : 850.571
Left Arm Q2 momentum : 1.96007
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.098
Left Arm D1 momentum : 1.96001
Left Arm D1 NMR : 0.725282
Left Arm Q3 power supply current : 917.834
Left Arm Q3 momentum : 1.95997
Left Arm Q3 gauss meter : 0.4594
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44123
Right Arm Q1 power supply : 861.555
Right Arm Q1 gauss meter : -0.021586
Right Arm Q2 power supply current : 625.548
Right Arm Q2 momentum : 1.44152
Right Arm Q2 gauss meter : 0.328
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 493.749
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 675.046
Right Arm Q3 momentum : 1.44151
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 4.6875
Left Arm Bottom VDC Current : 1.80664
Left Arm Top VDC voltage : 3.99854
Left Arm Bottom VDC voltage : 4.00098
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 3.99072
RICH Vmon 16 : 15.6
RICH Imon 16 : 0.04
RICH Vmon 17 : 0.2
RICH Imon 17 : 0
RICH Radiator Oxygen : -0.585938
RICH Radiator Moisture : 609.082
RICH Radiator Pressure : 7.61816
RICH Condensor temperature : -15.6758
RICH Gas Oxygen : 29.7852
RICH Gas Moisture : 26.5625
RICH Argon Flow : 1.17188
RICH Methane Flow : 800.391
RICH A Volts : 4.44727
RICH B Volts : 2.47803
Average current of the two cavities : 0.0274468
Current on Unser monitor : -10.5121
Current on Upstream bcm : 0.0297686
Current on Downstream bcm : 0.025125
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143517
Tiefenbach Hall A energy : 3654.59
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 0
HALLA:p : 3654.59
HALLA:dpp : 0
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1856.46
MBSY1c magnet current (amp) : 5.08079e-06
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577637
HacL_HPE1313A:0_Ch58 : -0.184082
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.0527344
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : -0.031503
IPM1H04A.YPOS : -0.039081
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 125
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.84845
SLI vert. size mm : 0
SLI y position : 2.20094
Waterfall Pump Speed : 3658
Target StepMot Pos. : 7.76307e+06