User name a-onl
Log entry time 17:35:46 on June 13, 2005
Entry number 146032
keyword=Start_Run_4570,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production with waterfall, tach=750,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4570 at Mon Jun 13 17:35:42 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 181.03
Left septum upper coil T : 6.43
Left septum lower coil T : 6.404
Right septum set current : 133.445
Right septum current readback : 130.737
Right septum upper coil T : 7.294
Right septum lower coil T : 6.576
Left Arm Q1 momentum : 1.96009
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.1001
Left Arm Q2 power supply current : 850.452
Left Arm Q2 momentum : 1.95979
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.051
Left Arm D1 momentum : 1.96
Left Arm D1 NMR : 0.725275
Left Arm Q3 power supply current : 917.864
Left Arm Q3 momentum : 1.96003
Left Arm Q3 gauss meter : 0.4594
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44141
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.021578
Right Arm Q2 power supply current : 625.302
Right Arm Q2 momentum : 1.44095
Right Arm Q2 gauss meter : 0.3288
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.638
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 675.014
Right Arm Q3 momentum : 1.44144
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -4.49219
Left Arm Bottom VDC Current : -4.93164
Left Arm Top VDC voltage : 3.98877
Left Arm Bottom VDC voltage : 4.00342
Right Arm Top VDC voltage : 4.00244
Right Arm Bottom VDC voltage : 3.99219
RICH Vmon 16 : 0.2
RICH Imon 16 : 0.04
RICH Vmon 17 : 0.2
RICH Imon 17 : 0
RICH Radiator Oxygen : -0.976562
RICH Radiator Moisture : 513.477
RICH Radiator Pressure : 9.59277
RICH Condensor temperature : -14.9434
RICH Gas Oxygen : -0.195312
RICH Gas Moisture : -0.488281
RICH Argon Flow : 1.26953
RICH Methane Flow : 800.098
RICH A Volts : 5.58936
RICH B Volts : 3.12256
Average current of the two cavities : 49.6511
Current on Unser monitor : 39.5599
Current on Upstream bcm : 49.148
Current on Downstream bcm : 50.1542
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 49.9479
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 0
HALLA:p : 3654.52
HALLA:dpp : -1.93722e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1856.46
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0579102
HacL_HPE1313A:0_Ch58 : -0.186523
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.0483398
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0.0144054
IPM1C12.YPOS : 0.0549355
IPM1H04A.XPOS : 1.85535
IPM1H04A.YPOS : -0.075877
IPM1H04B.XPOS : -0.00642496
IPM1H04B.YPOS : -0.0307467
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 135
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.152853
SLI Energy spread *10^5 : 3.82134
SLI x position : 1.29689
SLI vert. size mm : 0.155941
SLI y position : 1.40469
Waterfall Pump Speed : 3094.5
Target StepMot Pos. : 7.76307e+06