User name a-onl
Log entry time 20:52:51 on June 14, 2005
Entry number 146139
keyword=Start_Run_4596,Run_type=other,beam_energy=3.65,beam_raster=on,comment_text=density test ( with waterfall, tach=750, parity run 3437,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4596 at Tue Jun 14 20:52:47 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=187,ps2=65535,ps3=65535,ps4=65535,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Left septum set current : 184.671
Left septum current readback : 181.396
Left septum upper coil T : 6.341
Left septum lower coil T : 6.311
Right septum set current : 133.445
Right septum current readback : 131.714
Right septum upper coil T : 7.003
Right septum lower coil T : 6.26
Left Arm Q1 momentum : 1.96
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.10009
Left Arm Q2 power supply current : 850.607
Left Arm Q2 momentum : 1.96015
Left Arm Q2 gauss meter : -0.4478
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.311
Left Arm D1 momentum : 1.95999
Left Arm D1 NMR : 0.725275
Left Arm Q3 power supply current : 3.74339e-06
Left Arm Q3 momentum : 7.99374e-09
Left Arm Q3 gauss meter : 0.0016476
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.021593
Right Arm Q2 power supply current : 625.608
Right Arm Q2 momentum : 1.44166
Right Arm Q2 gauss meter : 0.3288
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.822
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 675
Right Arm Q3 momentum : 1.44142
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -0.439453
Left Arm Bottom VDC Current : -5.22461
Left Arm Top VDC voltage : 3.98877
Left Arm Bottom VDC voltage : 4.00146
Right Arm Top VDC voltage : 4.00635
Right Arm Bottom VDC voltage : 3.99609
RICH Vmon 16 : 2122.8
RICH Imon 16 : 0.11
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -0.976562
RICH Radiator Moisture : 458.691
RICH Radiator Pressure : 9.52539
RICH Condensor temperature : -15.5781
RICH Gas Oxygen : -0.292969
RICH Gas Moisture : -0.195312
RICH Argon Flow : 0.78125
RICH Methane Flow : 800.391
RICH A Volts : 5.5415
RICH B Volts : 3.09619
Average current of the two cavities : 50.3487
Current on Unser monitor : 40.5184
Current on Upstream bcm : 49.8751
Current on Downstream bcm : 50.8223
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 50.7782
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 8.55062
HALLA:p : 3654.52
HALLA:dpp : -1.94521e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1856.46
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0576172
HacL_HPE1313A:0_Ch58 : -0.18457
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.0473633
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0.00275809
IPM1C12.YPOS : 0.0710264
IPM1H04A.XPOS : 1.91056
IPM1H04A.YPOS : -0.0619127
IPM1H04B.XPOS : 0.0763894
IPM1H04B.YPOS : -0.0794516
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 140
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.245461
SLI Energy spread *10^5 : 6.13652
SLI x position : 1.29689
SLI vert. size mm : 0.234321
SLI y position : 1.40469
Waterfall Pump Speed : 3094.5
Target StepMot Pos. : 7.76307e+06