Beginning-of-run EPICS data for Run Number 4662 at Sat Jun 18 07:28:30 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 182.373
Left septum upper coil T : 6.405
Left septum lower coil T : 6.399
Right septum set current : 133.44
Right septum current readback : 130.493
Right septum upper coil T : 7.301
Right septum lower coil T : 6.619
Left Arm Q1 momentum : 1.95991
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.10006
Left Arm Q2 power supply current : 850.439
Left Arm Q2 momentum : 1.95976
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.206
Left Arm D1 momentum : 1.96
Left Arm D1 NMR : 0.725277
Left Arm Q3 power supply current : 917.868
Left Arm Q3 momentum : 1.96004
Left Arm Q3 gauss meter : 0.4594
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.662
Right Arm Q1 gauss meter : -0.0216
Right Arm Q2 power supply current : 625.373
Right Arm Q2 momentum : 1.44112
Right Arm Q2 gauss meter : 0.3289
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.829
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 674.973
Right Arm Q3 momentum : 1.44136
Right Arm Q3 gauss meter : 0.3029
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -6.00586
Left Arm Bottom VDC Current : 0.146484
Left Arm Top VDC voltage : 3.99854
Left Arm Bottom VDC voltage : 4.00244
Right Arm Top VDC voltage : 4.00635
Right Arm Bottom VDC voltage : 3.99609
RICH Vmon 16 : 2102.8
RICH Imon 16 : 0.11
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -1.36719
RICH Radiator Moisture : 406.25
RICH Radiator Pressure : 9.51172
RICH Condensor temperature : -16.4082
RICH Gas Oxygen : 25.7812
RICH Gas Moisture : 19.5312
RICH Argon Flow : 1.17188
RICH Methane Flow : 800.195
RICH A Volts : 5.54346
RICH B Volts : 3.09619
Average current of the two cavities : 60.1801
Current on Unser monitor : 47.3879
Current on Upstream bcm : 59.7777
Current on Downstream bcm : 60.5824
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 61.9736
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 3.77541
HALLA:p : 3654.52
HALLA:dpp : -2.11617e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.057373
HacL_HPE1313A:0_Ch58 : -0.185059
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : 0.046875
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : -0.0177939
IPM1C12.YPOS : 0.115547
IPM1H04A.XPOS : 1.8621
IPM1H04A.YPOS : -0.00143266
IPM1H04B.XPOS : 0.0224988
IPM1H04B.YPOS : -0.0130044
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 159
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.109752
SLI Energy spread *10^5 : 2.74379
SLI x position : 1.32671
SLI vert. size mm : 0.101834
SLI y position : 1.40469
Waterfall Pump Speed : 3094.5
Target StepMot Pos. : 7.76307e+06