User name a-onl
Log entry time 18:29:25 on June 18, 2005
Entry number 146497
keyword=Start_Run_4683,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production run, tach=748, ps5= 3 beam current 55 uA,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4683 at Sat Jun 18 18:29:22 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 178.345
Left septum upper coil T : 6.395
Left septum lower coil T : 6.388
Right septum set current : 133.445
Right septum current readback : 131.104
Right septum upper coil T : 7.098
Right septum lower coil T : 6.337
Left Arm Q1 momentum : 1.95991
Left Arm Q1 power supply : 1176.92
Left Arm Q1 gauss meter : 0.10007
Left Arm Q2 power supply current : 850.715
Left Arm Q2 momentum : 1.9604
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.252
Left Arm D1 momentum : 1.96
Left Arm D1 NMR : 0.725278
Left Arm Q3 power supply current : 917.875
Left Arm Q3 momentum : 1.96006
Left Arm Q3 gauss meter : 0.4593
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.021597
Right Arm Q2 power supply current : 625.305
Right Arm Q2 momentum : 1.44096
Right Arm Q2 gauss meter : 0.3288
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.829
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 675.062
Right Arm Q3 momentum : 1.44155
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -5.61523
Left Arm Bottom VDC Current : -0.0488281
Left Arm Top VDC voltage : 3.99512
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : 4.00684
Right Arm Bottom VDC voltage : 4
RICH Vmon 16 : 2102.2
RICH Imon 16 : 0.09
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -1.17188
RICH Radiator Moisture : 398.633
RICH Radiator Pressure : 9.52637
RICH Condensor temperature : -15.7246
RICH Gas Oxygen : 25.6836
RICH Gas Moisture : 19.4336
RICH Argon Flow : 0.976562
RICH Methane Flow : 800.195
RICH A Volts : 5.54688
RICH B Volts : 3.09863
Average current of the two cavities : 53.7188
Current on Unser monitor : 43.2195
Current on Upstream bcm : 53.1523
Current on Downstream bcm : 54.2853
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 54.1149
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 3.76406
HALLA:p : 3654.52
HALLA:dpp : -1.98489e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0575195
HacL_HPE1313A:0_Ch58 : -0.18457
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : 0.046875
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : -0.00745204
IPM1C12.YPOS : 0.0851494
IPM1H04A.XPOS : 1.89466
IPM1H04A.YPOS : 0.0129502
IPM1H04B.XPOS : 0.021913
IPM1H04B.YPOS : -0.0135422
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 154
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.0961843
SLI Energy spread *10^5 : 2.40461
SLI x position : 1.31925
SLI vert. size mm : 0.0978837
SLI y position : 1.40469
Waterfall Pump Speed : 3094.5
Target StepMot Pos. : 7.76307e+06