    User name a-onl

    Log entry time 16:10:10 on June 19, 2005

    Entry number 146622

    keyword=Start_Run_4713,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production run, tach=748, ps5= 3 beam current 55 uA,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 4713 at Sun Jun 19 16:10:07 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    
    ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
    
    Left septum set current : 184.671
    Left septum current readback : 181.274
    Left septum upper coil T : 6.284
    Left septum lower coil T : 6.279
    Right septum set current : 133.44
    Right septum current readback : 131.104
    Right septum upper coil T : 7.243
    Right septum lower coil T : 6.535
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10008
    Left Arm Q2 power supply current : 850.553
    Left Arm Q2 momentum : 1.96002
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.252
    Left Arm D1 momentum : 1.95999
    Left Arm D1 NMR : 0.725274
    Left Arm Q3 power supply current : 917.862
    Left Arm Q3 momentum : 1.96003
    Left Arm Q3 gauss meter : 0.4594
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44132
    Right Arm Q1 power supply : 861.608
    Right Arm Q1 gauss meter : -0.021591
    Right Arm Q2 power supply current : 625.593
    Right Arm Q2 momentum : 1.44163
    Right Arm Q2 gauss meter : 0.3289
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 495.824
    Right Arm D1 momentum : 1.4414
    Right Arm D1 NMR : 0.534885
    Right Arm Q3 power supply current : 675.007
    Right Arm Q3 momentum : 1.44143
    Right Arm Q3 gauss meter : 0.303
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 0.976562
    Left Arm Bottom VDC Current : -2.05078
    Left Arm Top VDC voltage : 3.99512
    Left Arm Bottom VDC voltage : 3.99902
    Right Arm Top VDC voltage : 4.00244
    Right Arm Bottom VDC voltage : 3.99316
    RICH Vmon 16 : 2102.8
    RICH Imon 16 : 0.04
    RICH Vmon 17 : 401
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.878906
    RICH Radiator Moisture : 394.238
    RICH Radiator Pressure : 9.54297
    RICH Condensor temperature : -17.3848
    RICH Gas Oxygen : 25.6836
    RICH Gas Moisture : 18.1641
    RICH Argon Flow : 1.17188
    RICH Methane Flow : 800.098
    RICH A Volts : 5.56445
    RICH B Volts : 3.11084
    Average current of the two cavities : 0.0273437
    Current on Unser monitor : -10.7491
    Current on Upstream bcm : 0.0313994
    Current on Downstream bcm : 0.023288
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143517
    Tiefenbach Hall A energy : 3654.59
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 3.95157
    HALLA:p : 3654.59
    HALLA:dpp : 0
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1857.5
    MBSY1c magnet current (amp) : 152.504
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0578125
    HacL_HPE1313A:0_Ch58 : -0.183594
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : 0.0463867
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 1.37478
    IPM1H04A.YPOS : 0.400266
    IPM1H04B.XPOS : -0.243243
    IPM1H04B.YPOS : -0.0662385
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 90
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.54161
    SLI vert. size mm : 0
    SLI y position : 1.88545
    Waterfall Pump Speed : 2956.5
    Target StepMot Pos. : 7.76307e+06