NEXT
User name a-onl
Log entry time 18:09:17 on June 20, 2005
Entry number 146721
keyword=Start_Run_4747,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production run, tach=605, ps5= 3 beam current 55 uA,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4747 at Mon Jun 20 18:09:13 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 181.763
Left septum upper coil T : 6.426
Left septum lower coil T : 6.421
Right septum set current : 133.44
Right septum current readback : 131.226
Right septum upper coil T : 7.324
Right septum lower coil T : 6.602
Left Arm Q1 momentum : 1.95991
Left Arm Q1 power supply : 1176.92
Left Arm Q1 gauss meter : 0.10007
Left Arm Q2 power supply current : 850.51
Left Arm Q2 momentum : 1.95993
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.279
Left Arm D1 momentum : 1.96
Left Arm D1 NMR : 0.725277
Left Arm Q3 power supply current : 917.898
Left Arm Q3 momentum : 1.96011
Left Arm Q3 gauss meter : 0.4594
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.0216
Right Arm Q2 power supply current : 625.707
Right Arm Q2 momentum : 1.44189
Right Arm Q2 gauss meter : 0.3289
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.829
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534886
Right Arm Q3 power supply current : 675.083
Right Arm Q3 momentum : 1.44159
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -5.32227
Left Arm Bottom VDC Current : -4.88281
Left Arm Top VDC voltage : 3.99854
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : 4.00537
Right Arm Bottom VDC voltage : 3.99707
RICH Vmon 16 : 2102.6
RICH Imon 16 : 0.09
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -1.36719
RICH Radiator Moisture : 386.426
RICH Radiator Pressure : 9.59424
RICH Condensor temperature : -16.0176
RICH Gas Oxygen : 26.5625
RICH Gas Moisture : 18.5547
RICH Argon Flow : 1.17188
RICH Methane Flow : 800.293
RICH A Volts : 5.58008
RICH B Volts : 3.11523
Average current of the two cavities : 54.5792
Current on Unser monitor : 42.7315
Current on Upstream bcm : 54.0915
Current on Downstream bcm : 55.0669
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 54.8349
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 0
HALLA:p : 3654.52
HALLA:dpp : -2.13865e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577637
HacL_HPE1313A:0_Ch58 : -0.184082
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : 0.0449219
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0.00425601
IPM1C12.YPOS : 0.107431
IPM1H04A.XPOS : 1.884
IPM1H04A.YPOS : 0.00193477
IPM1H04B.XPOS : 0.000602126
IPM1H04B.YPOS : -0.0188451
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 162
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.0516967
SLI Energy spread *10^5 : 1.29242
SLI x position : 1.36398
SLI vert. size mm : 0.0934172
SLI y position : 1.40469
Waterfall Pump Speed : 2956.5
Target StepMot Pos. : 7.76307e+06