User name a-onl
Log entry time 10:45:58 on June 21, 2005
Entry number 146804
keyword=Start_Run_4778,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production run, tach=605, ps5= 3 beam current 55 uA,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4778 at Tue Jun 21 10:45:55 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 180.176
Left septum upper coil T : 6.429
Left septum lower coil T : 6.427
Right septum set current : 133.44
Right septum current readback : 130.127
Right septum upper coil T : 7.12
Right septum lower coil T : 6.427
Left Arm Q1 momentum : 1.96
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.10009
Left Arm Q2 power supply current : 850.629
Left Arm Q2 momentum : 1.9602
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.273
Left Arm D1 momentum : 1.96
Left Arm D1 NMR : 0.725277
Left Arm Q3 power supply current : 917.833
Left Arm Q3 momentum : 1.95997
Left Arm Q3 gauss meter : 0.4593
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.0216
Right Arm Q2 power supply current : 625.708
Right Arm Q2 momentum : 1.44189
Right Arm Q2 gauss meter : 0.3289
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.821
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534885
Right Arm Q3 power supply current : 674.958
Right Arm Q3 momentum : 1.44132
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -5.22461
Left Arm Bottom VDC Current : 0.878906
Left Arm Top VDC voltage : 3.99609
Left Arm Bottom VDC voltage : 4.00439
Right Arm Top VDC voltage : 4.00195
Right Arm Bottom VDC voltage : 3.9917
RICH Vmon 16 : 2103
RICH Imon 16 : 0.08
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -1.26953
RICH Radiator Moisture : 382.129
RICH Radiator Pressure : 9.54346
RICH Condensor temperature : -15.627
RICH Gas Oxygen : 38.4766
RICH Gas Moisture : 17.1875
RICH Argon Flow : 1.07422
RICH Methane Flow : 800.488
RICH A Volts : 5.56543
RICH B Volts : 3.10791
Average current of the two cavities : 55.7362
Current on Unser monitor : 44.9021
Current on Upstream bcm : 55.0319
Current on Downstream bcm : 56.4405
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 56.0366
Tiefenbach Hall A energy : 3654.52
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 0
HALLA:p : 3654.53
HALLA:dpp : -1.87029e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.057373
HacL_HPE1313A:0_Ch58 : -0.184082
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : 0.0449219
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0.00146958
IPM1C12.YPOS : 0.0870158
IPM1H04A.XPOS : 1.86244
IPM1H04A.YPOS : 0.00262958
IPM1H04B.XPOS : 0.00508726
IPM1H04B.YPOS : -0.0395212
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 169
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.112818
SLI Energy spread *10^5 : 2.82044
SLI x position : 1.35652
SLI vert. size mm : 0.129263
SLI y position : 1.40469
Waterfall Pump Speed : 2956.5
Target StepMot Pos. : 7.76307e+06