    User name a-onl

    Log entry time 00:06:12 on June 22, 2005

    Entry number 146856

    keyword=Start_Run_4796,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=production run, tach=605, ps5= 3 beam current 55 uA,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 4796 at Wed Jun 22 00:05:29 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    
    ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
    
    Left septum set current : MSEPLSETI --- Invalid channel name
    Left septum current readback : MSEPLMIR --- Invalid channel name
    Left septum upper coil T : MSEPLUPCOILT --- Invalid channel name
    Left septum lower coil T : MSEPLLOWCOILT --- Invalid channel name
    Right septum set current : MSEPRSETI --- Invalid channel name
    Right septum current readback : MSEPRMIR --- Invalid channel name
    Right septum upper coil T : MSEPRUPCOILT --- Invalid channel name
    Right septum lower coil T : MSEPRLOWCOILT --- Invalid channel name
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10011
    Left Arm Q2 power supply current : 850.674
    Left Arm Q2 momentum : 1.96031
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.27
    Left Arm D1 momentum : 1.96
    Left Arm D1 NMR : 0.725275
    Left Arm Q3 power supply current : 917.844
    Left Arm Q3 momentum : 1.95999
    Left Arm Q3 gauss meter : 0.4594
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44132
    Right Arm Q1 power supply : 861.555
    Right Arm Q1 gauss meter : -0.021599
    Right Arm Q2 power supply current : 625.379
    Right Arm Q2 momentum : 1.44113
    Right Arm Q2 gauss meter : 0.3288
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 495.823
    Right Arm D1 momentum : 1.4414
    Right Arm D1 NMR : 0.534885
    Right Arm Q3 power supply current : 675.034
    Right Arm Q3 momentum : 1.44149
    Right Arm Q3 gauss meter : 0.303
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 0.634766
    Left Arm Bottom VDC Current : -3.85742
    Left Arm Top VDC voltage : 3.99219
    Left Arm Bottom VDC voltage : 3.99805
    Right Arm Top VDC voltage : 4.00342
    Right Arm Bottom VDC voltage : 3.99219
    RICH Vmon 16 : 2103.4
    RICH Imon 16 : 0.09
    RICH Vmon 17 : 401.2
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.78125
    RICH Radiator Moisture : 373.34
    RICH Radiator Pressure : 9.52881
    RICH Condensor temperature : -15.8223
    RICH Gas Oxygen : 38.4766
    RICH Gas Moisture : 17.5781
    RICH Argon Flow : 1.26953
    RICH Methane Flow : 800.391
    RICH A Volts : 5.5498
    RICH B Volts : 3.09717
    Average current of the two cavities : 54.1894
    Current on Unser monitor : 42.6038
    Current on Upstream bcm : 53.7224
    Current on Downstream bcm : 54.6564
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 55.4813
    Tiefenbach Hall A energy : 3654.53
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 0.0352914
    HALLA:p : 3654.53
    HALLA:dpp : -1.82753e-05
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1857.5
    MBSY1c magnet current (amp) : 152.504
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0573242
    HacL_HPE1313A:0_Ch58 : -0.183594
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : 0.0454102
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : 0.0078277
    IPM1C12.YPOS : 0.0840186
    IPM1H04A.XPOS : 1.88092
    IPM1H04A.YPOS : -0.00374746
    IPM1H04B.XPOS : -0.00127596
    IPM1H04B.YPOS : -0.0313886
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 171
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : Yes
    SLI horiz size mm : 0.134219
    SLI Energy spread *10^5 : 3.35547
    SLI x position : 1.35652
    SLI vert. size mm : 0.132971
    SLI y position : 1.40469
    Waterfall Pump Speed : 2956.5
    Target StepMot Pos. : 7.76307e+06