User name a-onl
Log entry time 23:03:08 on June 23, 2005
Entry number 147035
keyword=Start_Run_4849,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=Waterfall, Tach 605, Beam 55uA, production,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
Beginning-of-run EPICS data for Run Number 4849 at Thu Jun 23 23:03:04 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 180.786
Left septum upper coil T : 6.406
Left septum lower coil T : 6.391
Right septum set current : 133.44
Right septum current readback : 132.08
Right septum upper coil T : 7.214
Right septum lower coil T : 6.531
Left Arm Q1 momentum : 1.96
Left Arm Q1 power supply : 1176.97
Left Arm Q1 gauss meter : 0.10008
Left Arm Q2 power supply current : 850.502
Left Arm Q2 momentum : 1.95991
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.123
Left Arm D1 momentum : 1.96001
Left Arm D1 NMR : 0.725279
Left Arm Q3 power supply current : 917.884
Left Arm Q3 momentum : 1.96008
Left Arm Q3 gauss meter : 0.4594
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44132
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.021579
Right Arm Q2 power supply current : 625.355
Right Arm Q2 momentum : 1.44103
Right Arm Q2 gauss meter : 0.3288
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.826
Right Arm D1 momentum : 1.44139
Right Arm D1 NMR : 0.534884
Right Arm Q3 power supply current : 674.923
Right Arm Q3 momentum : 1.44125
Right Arm Q3 gauss meter : 0.3029
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : 1.66016
Left Arm Bottom VDC Current : -0.0488281
Left Arm Top VDC voltage : 3.99609
Left Arm Bottom VDC voltage : 4.00244
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 3.98877
RICH Vmon 16 : 2102.8
RICH Imon 16 : 0.08
RICH Vmon 17 : 401
RICH Imon 17 : 0
RICH Radiator Oxygen : -0.488281
RICH Radiator Moisture : 354.004
RICH Radiator Pressure : 9.5542
RICH Condensor temperature : -16.3105
RICH Gas Oxygen : 26.3672
RICH Gas Moisture : 16.5039
RICH Argon Flow : 0.878906
RICH Methane Flow : 800.488
RICH A Volts : 5.56836
RICH B Volts : 3.10596
Average current of the two cavities : 54.1407
Current on Unser monitor : 43.0743
Current on Upstream bcm : 53.3045
Current on Downstream bcm : 54.977
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 55.4379
Tiefenbach Hall A energy : 3654.59
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 3.88808
HALLA:p : 3654.59
HALLA:dpp : 0
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577148
HacL_HPE1313A:0_Ch58 : -0.183594
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : 0.0454102
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : -0.00364965
IPM1C12.YPOS : 0.0819976
IPM1H04A.XPOS : 2.01355
IPM1H04A.YPOS : 0.0050965
IPM1H04B.XPOS : 0.140928
IPM1H04B.YPOS : -0.0708297
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 171
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.0834389
SLI Energy spread *10^5 : 2.08597
SLI x position : 1.34161
SLI vert. size mm : 0.1534
SLI y position : 1.40469
Waterfall Pump Speed : 2956.5
Target StepMot Pos. : 7.76307e+06