    User name a-onl

    Log entry time 10:06:48 on June 25, 2005

    Entry number 147185

    keyword=Start_Run_4897,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=WATERFALL TACHEO AT 600 - Current 50 uA - PRODUCTION,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 4897 at Sat Jun 25 10:06:45 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
    
    Left septum set current : 184.671
    Left septum current readback : 183.228
    Left septum upper coil T : 6.401
    Left septum lower coil T : 6.39
    Right septum set current : 133.445
    Right septum current readback : 130.859
    Right septum upper coil T : 7.144
    Right septum lower coil T : 6.45
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10005
    Left Arm Q2 power supply current : 850.557
    Left Arm Q2 momentum : 1.96003
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.125
    Left Arm D1 momentum : 1.96001
    Left Arm D1 NMR : 0.725279
    Left Arm Q3 power supply current : 917.828
    Left Arm Q3 momentum : 1.95996
    Left Arm Q3 gauss meter : 0.4593
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44123
    Right Arm Q1 power supply : 861.608
    Right Arm Q1 gauss meter : -0.021579
    Right Arm Q2 power supply current : 625.514
    Right Arm Q2 momentum : 1.44144
    Right Arm Q2 gauss meter : 0.3288
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 495.819
    Right Arm D1 momentum : 1.4414
    Right Arm D1 NMR : 0.534884
    Right Arm Q3 power supply current : 674.903
    Right Arm Q3 momentum : 1.44121
    Right Arm Q3 gauss meter : 0.3029
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 0.732422
    Left Arm Bottom VDC Current : 1.36719
    Left Arm Top VDC voltage : 3.99609
    Left Arm Bottom VDC voltage : 4.00244
    Right Arm Top VDC voltage : 4
    Right Arm Bottom VDC voltage : 3.99072
    RICH Vmon 16 : 2102.6
    RICH Imon 16 : 0.09
    RICH Vmon 17 : 401
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.390625
    RICH Radiator Moisture : 343.75
    RICH Radiator Pressure : 9.57275
    RICH Condensor temperature : -16.2129
    RICH Gas Oxygen : 161.816
    RICH Gas Moisture : 16.5039
    RICH Argon Flow : 0.976562
    RICH Methane Flow : 800.391
    RICH A Volts : 5.56836
    RICH B Volts : 3.104
    Average current of the two cavities : 49.1944
    Current on Unser monitor : 37.1847
    Current on Upstream bcm : 48.7924
    Current on Downstream bcm : 49.5964
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 50.2148
    Tiefenbach Hall A energy : 3654.59
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 3.96554
    HALLA:p : 3654.59
    HALLA:dpp : 0
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1857.5
    MBSY1c magnet current (amp) : 152.504
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0573242
    HacL_HPE1313A:0_Ch58 : -0.18457
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : 0.0439453
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : -0.0155508
    IPM1C12.YPOS : 0.0665134
    IPM1H04A.XPOS : 2.0003
    IPM1H04A.YPOS : 0.0279757
    IPM1H04B.XPOS : 0.125142
    IPM1H04B.YPOS : -0.0405519
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 166
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : Yes
    SLI horiz size mm : 0.0852191
    SLI Energy spread *10^5 : 2.13048
    SLI x position : 1.34161
    SLI vert. size mm : 0.125909
    SLI y position : 1.39718
    Waterfall Pump Speed : 2956.5
    Target StepMot Pos. : 7.76307e+06