    User name a-onl

    Log entry time 16:07:11 on June 25, 2005

    Entry number 147205

    keyword=Start_Run_4905,Run_type=production,beam_energy=3.65,beam_raster=on,comment_text=WATERFALL TACHEO AT 600 - Current 45 uA - PRODUCTION,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=Waterfall
    Beginning-of-run EPICS data for Run Number 4905 at Sat Jun 25 16:07:08 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    ps1=18700,ps2=200,ps3=4000,ps4=220,ps5=3,ps6=800,ps7=1,ps8=65535
    
    Left septum set current : 184.671
    Left septum current readback : 178.711
    Left septum upper coil T : 6.359
    Left septum lower coil T : 6.348
    Right septum set current : 133.445
    Right septum current readback : 130.737
    Right septum upper coil T : 7.006
    Right septum lower coil T : 6.274
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10007
    Left Arm Q2 power supply current : 850.488
    Left Arm Q2 momentum : 1.95988
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.126
    Left Arm D1 momentum : 1.96
    Left Arm D1 NMR : 0.725277
    Left Arm Q3 power supply current : 917.847
    Left Arm Q3 momentum : 1.96
    Left Arm Q3 gauss meter : 0.4594
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44123
    Right Arm Q1 power supply : 861.555
    Right Arm Q1 gauss meter : -0.021597
    Right Arm Q2 power supply current : 625.614
    Right Arm Q2 momentum : 1.44167
    Right Arm Q2 gauss meter : 0.3289
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 495.818
    Right Arm D1 momentum : 1.44139
    Right Arm D1 NMR : 0.534884
    Right Arm Q3 power supply current : 675.026
    Right Arm Q3 momentum : 1.44147
    Right Arm Q3 gauss meter : 0.303
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -4.29688
    Left Arm Bottom VDC Current : 0.976562
    Left Arm Top VDC voltage : 4
    Left Arm Bottom VDC voltage : 4.00146
    Right Arm Top VDC voltage : 3.99902
    Right Arm Bottom VDC voltage : 3.9917
    RICH Vmon 16 : 2102.8
    RICH Imon 16 : 0.08
    RICH Vmon 17 : 401.2
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.78125
    RICH Radiator Moisture : 339.844
    RICH Radiator Pressure : 9.56934
    RICH Condensor temperature : -16.4082
    RICH Gas Oxygen : 28.418
    RICH Gas Moisture : 16.5039
    RICH Argon Flow : 0.878906
    RICH Methane Flow : 800.195
    RICH A Volts : 5.56592
    RICH B Volts : 3.10693
    Average current of the two cavities : 43.4457
    Current on Unser monitor : 32.1173
    Current on Upstream bcm : 42.8096
    Current on Downstream bcm : 44.0819
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 43.5815
    Tiefenbach Hall A energy : 3654.59
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 3.9902
    HALLA:p : 3654.59
    HALLA:dpp : 0
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1857.5
    MBSY1c magnet current (amp) : 152.504
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0575684
    HacL_HPE1313A:0_Ch58 : -0.18457
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : 0.0439453
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : -0.0310563
    IPM1C12.YPOS : 0.0579
    IPM1H04A.XPOS : 1.99234
    IPM1H04A.YPOS : 0.0607231
    IPM1H04B.XPOS : 0.112846
    IPM1H04B.YPOS : 0.0116144
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 158
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : Yes
    SLI horiz size mm : 0.0749032
    SLI Energy spread *10^5 : 1.87258
    SLI x position : 1.34161
    SLI vert. size mm : 0.140781
    SLI y position : 1.40469
    Waterfall Pump Speed : 2956.5
    Target StepMot Pos. : 7.76307e+06