NEXT
User name a-onl
Log entry time 11:00:04 on June 28, 2005
Entry number 147336
keyword=Start_Run_4940,Run_type=other,beam_energy=3.65,beam_raster=on,comment_text=Carbon Thick - Bull's eye scan studies - Raster Size 1.6x1.6 mm2,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=thick 12C target
Beginning-of-run EPICS data for Run Number 4940 at Tue Jun 28 11:00:02 EDT 2005
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = R-arm scint trig
; T2 = R-arm effic trig (2/3)
; T3 = L-arm scint trig
; T4 = L-arm effic trig (2/3)
; T5 = T1.and.T3
; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
; T7 = T5.and.T6 (Kaon coincidences)
; T8 = 1024 Hz pulser
ps1=300,ps2=40,ps3=80,ps4=80,ps5=1,ps6=300,ps7=1,ps8=65535
Left septum set current : 184.671
Left septum current readback : 181.519
Left septum upper coil T : 6.294
Left septum lower coil T : 6.303
Right septum set current : 133.445
Right septum current readback : 130.493
Right septum upper coil T : 7.289
Right septum lower coil T : 6.651
Left Arm Q1 momentum : 1.96
Left Arm Q1 power supply : 1176.92
Left Arm Q1 gauss meter : 0.10007
Left Arm Q2 power supply current : 850.545
Left Arm Q2 momentum : 1.9601
Left Arm Q2 gauss meter : -0.4479
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 666.179
Left Arm D1 momentum : 1.96001
Left Arm D1 NMR : 0.72528
Left Arm Q3 power supply current : 917.792
Left Arm Q3 momentum : 1.95988
Left Arm Q3 gauss meter : 0.4593
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 1.44141
Right Arm Q1 power supply : 861.608
Right Arm Q1 gauss meter : -0.021599
Right Arm Q2 power supply current : 625.564
Right Arm Q2 momentum : 1.44156
Right Arm Q2 gauss meter : 0.3289
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.795
Right Arm D1 momentum : 1.4414
Right Arm D1 NMR : 0.534886
Right Arm Q3 power supply current : 674.912
Right Arm Q3 momentum : 1.44123
Right Arm Q3 gauss meter : 0.303
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.44141
Left Arm Bottom VDC Current : 1.36719
Left Arm Top VDC voltage : 4.00195
Left Arm Bottom VDC voltage : 4.00146
Right Arm Top VDC voltage : 4.00342
Right Arm Bottom VDC voltage : 3.99609
RICH Vmon 16 : 2103
RICH Imon 16 : 0.06
RICH Vmon 17 : 401.2
RICH Imon 17 : 0
RICH Radiator Oxygen : -0.683594
RICH Radiator Moisture : 315.039
RICH Radiator Pressure : 9.54102
RICH Condensor temperature : -16.3105
RICH Gas Oxygen : 161.621
RICH Gas Moisture : 16.4062
RICH Argon Flow : 1.17188
RICH Methane Flow : 800.098
RICH A Volts : 5.56348
RICH B Volts : 3.10645
Average current of the two cavities : 53.4068
Current on Unser monitor : 42.7368
Current on Upstream bcm : 52.8271
Current on Downstream bcm : 53.9864
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 58.6539
Tiefenbach Hall A energy : 3654.53
Tiefenbach Hall C energy : 1852.32
Delta(E)/E width (MV_AI_DXWID) : 4.49865
HALLA:p : 3654.53
HALLA:dpp : -1.90576e-05
MBSY1c Hall A Beam energy : 3660.98
MBSY3c Hall C Beam energy : 1857.5
MBSY1c magnet current (amp) : 152.504
MBSY1c Bdl : 913602
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.0577148
HacL_HPE1313A:0_Ch58 : -0.183594
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : 0.0444336
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 32
Left Arm Scattering Angle : 12.5054
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 12.4999
IPM1C12.XPOS : 0.0143881
IPM1C12.YPOS : 0.0593567
IPM1H04A.XPOS : 2.02588
IPM1H04A.YPOS : 0.0436122
IPM1H04B.XPOS : 0.18639
IPM1H04B.YPOS : -0.00113428
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -35.0008
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 23.26
Laser attenuation Hall A : 188
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 0
Beam Half-wave plate (off=out) : OUT
SLI data valid? : Yes
SLI horiz size mm : 0.123439
SLI Energy spread *10^5 : 3.08597
SLI x position : 1.3118
SLI vert. size mm : 0.138493
SLI y position : 1.40469
Waterfall Pump Speed : 2956.5
Target StepMot Pos. : 3.14342e+06