    User name a-onl

    Log entry time 11:29:34 on June 28, 2005

    Entry number 147344

    keyword=Start_Run_4944,Run_type=other,beam_energy=3.65,beam_raster=on,comment_text=Carbon Thick - 5 uA - Bull's eye scan studies - Raster OFF,daq_mode=RICHNF1,kin_name=,leftarm_p=1.96,leftarm_theta=6.0,rightarm_p=1.44,rightarm_theta=6.0,target_type=thick 12C target
    Beginning-of-run EPICS data for Run Number 4944 at Tue Jun 28 11:29:32 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm scint trig              
    ; T2 = R-arm effic trig (2/3)
    ; T3 = L-arm scint trig
    ; T4 = L-arm effic trig (2/3)
    ; T5 = T1.and.T3
    ; T6 = Clean Kaon (T3.and.A2.and.NOT.A1)
    ; T7 = T5.and.T6 (Kaon coincidences)
    ; T8 = 1024 Hz pulser
    ps1=30,ps2=4,ps3=8,ps4=8,ps5=1,ps6=30,ps7=1,ps8=65535
    
    Left septum set current : 184.671
    Left septum current readback : 182.373
    Left septum upper coil T : 6.244
    Left septum lower coil T : 6.253
    Right septum set current : 133.445
    Right septum current readback : 130.737
    Right septum upper coil T : 7.052
    Right septum lower coil T : 6.403
    Left Arm Q1 momentum : 1.96
    Left Arm Q1 power supply : 1176.97
    Left Arm Q1 gauss meter : 0.10009
    Left Arm Q2 power supply current : 850.59
    Left Arm Q2 momentum : 1.96011
    Left Arm Q2 gauss meter : -0.4479
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 666.186
    Left Arm D1 momentum : 1.96
    Left Arm D1 NMR : 0.725277
    Left Arm Q3 power supply current : 917.844
    Left Arm Q3 momentum : 1.95999
    Left Arm Q3 gauss meter : 0.4593
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.44132
    Right Arm Q1 power supply : 861.608
    Right Arm Q1 gauss meter : -0.021579
    Right Arm Q2 power supply current : 625.633
    Right Arm Q2 momentum : 1.44172
    Right Arm Q2 gauss meter : 0.3288
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 495.787
    Right Arm D1 momentum : 1.4414
    Right Arm D1 NMR : 0.534885
    Right Arm Q3 power supply current : 674.983
    Right Arm Q3 momentum : 1.44138
    Right Arm Q3 gauss meter : 0.3029
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -1.41602
    Left Arm Bottom VDC Current : -0.585938
    Left Arm Top VDC voltage : 3.99609
    Left Arm Bottom VDC voltage : 4.00244
    Right Arm Top VDC voltage : 4.00195
    Right Arm Bottom VDC voltage : 3.99561
    RICH Vmon 16 : 2102.6
    RICH Imon 16 : 0.04
    RICH Vmon 17 : 401
    RICH Imon 17 : 0
    RICH Radiator Oxygen : -0.292969
    RICH Radiator Moisture : 316.602
    RICH Radiator Pressure : 9.5415
    RICH Condensor temperature : -17.2383
    RICH Gas Oxygen : 141.504
    RICH Gas Moisture : 16.6992
    RICH Argon Flow : 0.78125
    RICH Methane Flow : 800
    RICH A Volts : 5.55664
    RICH B Volts : 3.10352
    Average current of the two cavities : 0.0273002
    Current on Unser monitor : -10.9671
    Current on Upstream bcm : 0.0316556
    Current on Downstream bcm : 0.0229448
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143517
    Tiefenbach Hall A energy : 3654.59
    Tiefenbach Hall C energy : 1852.32
    Delta(E)/E width (MV_AI_DXWID) : 0
    HALLA:p : 3654.59
    HALLA:dpp : 0
    MBSY1c Hall A Beam energy : 3660.98
    MBSY3c Hall C Beam energy : 1857.5
    MBSY1c magnet current (amp) : 152.504
    MBSY1c Bdl : 913602
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0577148
    HacL_HPE1313A:0_Ch58 : -0.183105
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : 0.0449219
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 32
    Left Arm Scattering Angle : 12.5054
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : -34.2
    Right Arm Scattering Angle : 12.4999
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 0
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.20621
    SLI vert. size mm : 0
    SLI y position : 1.63756
    Waterfall Pump Speed : 2956.5
    Target StepMot Pos. : 3.14342e+06