• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:34:29 on July 19, 2005

    Entry number 148620

    keyword=Start_Run_2160,Run_type=spot++,beam_energy=2.750,beam_raster=on,comment_text=spot++ with no target,daq_mode=twoarm,kin_name=,leftarm_p=2.736,leftarm_theta=6.0,rightarm_p=2.732,rightarm_theta=6.0,target_type=No target
    Beginning-of-run EPICS data for Run Number 2160 at Tue Jul 19 19:23:48 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm S0 trigger (new HAPPEX S0)
    ; T2 = R-arm HAPPEX detector trigger
    ; T3 = L-arm S0 trigger (new HAPPEX S0)
    ; T4 = L-arm HAPPEX detector trigger
    ; T5 = R-arm Qsq scanner scint.
    ; T6 = L-arm Qsq scanner scint
    ; T7 = R-arm S2m trigger
    ; T8 = L-arm S2m trigger
    ; T9 = 10 Hz pulser (cannot be prescaled; don't even try)
    
    ps1=4,ps2=150,ps3=1,ps4=130,ps5=9999,ps6=9999,ps7=1,ps8=1
    
    
    Left septum set current : 257.409
    Left septum current readback : 254.517
    Left septum upper coil T : 6.162
    Left septum lower coil T : 6.216
    Right septum set current : 252.929
    Right septum current readback : 251.099
    Right septum upper coil T : 6.553
    Right septum lower coil T : 5.992
    Left Arm Q1 momentum : 2.73215
    Left Arm Q1 power supply : 1640.65
    Left Arm Q1 gauss meter : -0.13856
    Left Arm Q2 power supply current : 1185.51
    Left Arm Q2 momentum : 2.73191
    Left Arm Q2 gauss meter : 0.6239
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 949.016
    Left Arm D1 momentum : 2.732
    Left Arm D1 NMR : 1.01139
    Left Arm Q3 power supply current : 1279.41
    Left Arm Q3 momentum : 2.73208
    Left Arm Q3 gauss meter : -0.64
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.73211
    Right Arm Q1 power supply : 1633.17
    Right Arm Q1 gauss meter : -0.04064
    Right Arm Q2 power supply current : 1185.7
    Right Arm Q2 momentum : 2.73233
    Right Arm Q2 gauss meter : 0.6224
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 971.415
    Right Arm D1 momentum : 2.73199
    Right Arm D1 NMR : 1.01381
    Right Arm Q3 power supply current : 1279.37
    Right Arm Q3 momentum : 2.73201
    Right Arm Q3 gauss meter : 0.5741
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 0.683594
    Left Arm Bottom VDC Current : 0.732422
    Left Arm Top VDC voltage : 0.00976562
    Left Arm Bottom VDC voltage : 0.0112305
    Right Arm Top VDC voltage : -0.00732422
    Right Arm Bottom VDC voltage : 0.00585938
    RICH Vmon 16 : CAENdatC1M2Ch16.NLH --- Invalid channel name
    RICH Imon 16 : CAENdatC1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : CAENdatC1M2Ch17.NLH --- Invalid channel name
    RICH Imon 17 : CAENdatC1M2Ch17.NLK --- Invalid channel name
    RICH Radiator Oxygen : HacRICH_HPE1313A:0_RadO2 --- Invalid channel name
    RICH Radiator Moisture : HacRICH_HPE1313A:0_RadMoist --- Invalid channel name
    RICH Radiator Pressure : HacRICH_HPE1313A:0_Ch9 --- Invalid channel name
    RICH Condensor temperature : HacRICH_HPE1313A:0_Cond_Temp --- Invalid channel name
    RICH Gas Oxygen : HacRICH_HPE1313A:0_GasO2 --- Invalid channel name
    RICH Gas Moisture : HacRICH_HPE1313A:0_GasMoist --- Invalid channel name
    RICH Argon Flow : HacRICH_HPE1313A:0_Ch4 --- Invalid channel name
    RICH Methane Flow : HacRICH_HPE1313A:0_Ch5 --- Invalid channel name
    RICH A Volts : HacRICH_HPE1313A:0_Ch10 --- Invalid channel name
    RICH B Volts :
    Average current of the two cavities : 14.294
    Current on Unser monitor : 11.1725
    Current on Upstream bcm : 14.1439
    Current on Downstream bcm : 14.444
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 23.464
    Tiefenbach Hall A energy : 2753.45
    Tiefenbach Hall C energy : 1853.05
    Delta(E)/E width (MV_AI_DXWID) : 2.13784
    HALLA:p : 2753.45
    HALLA:dpp : 0.000133977
    MBSY1c Hall A Beam energy : 2757.26
    MBSY3c Hall C Beam energy : 1857.18
    MBSY1c magnet current (amp) : 114.771
    MBSY1c Bdl : 688077
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0581543
    HacL_HPE1313A:0_Ch58 : -0.182129
    HacL_HPE1313A:0_Ch55 : 25.4883
    HacL_HPE1313A:0_Ch54 : 0.0415039
    Left Arm Angle Floor Angle :
    Left Arm Angle Vernier :
    Left Arm Scattering Angle :
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 12.697
    IPM1C12.XPOS : -0.542519
    IPM1C12.YPOS : 0.0250142
    IPM1H04A.XPOS : 0.67206
    IPM1H04A.YPOS : -0.334197
    IPM1H04B.XPOS : 0.0569774
    IPM1H04B.YPOS : -0.15165
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 111
    Laser power Hall A :
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1250
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : No
    SLI horiz size mm : 0.285583
    SLI Energy spread *10^5 :
    SLI x position : 1.34161
    SLI vert. size mm :
    SLI y position : 1.40469
    Waterfall Pump Speed :
    Target StepMot Pos. :