• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:49:32 on July 20, 2005

    Entry number 148753

    keyword=Start_Run_2177,Run_type=alignment,beam_energy=2.750,beam_raster=on,comment_text=New T0,daq_mode=twoarm,kin_name=,leftarm_p=2.736,leftarm_theta=6.0,rightarm_p=2.732,rightarm_theta=6.0,target_type=No target
    Beginning-of-run EPICS data for Run Number 2177 at Wed Jul 20 19:48:10 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm S0 trigger (new HAPPEX S0)
    ; T2 = R-arm HAPPEX detector trigger
    ; T3 = L-arm S0 trigger (new HAPPEX S0)
    ; T4 = L-arm HAPPEX detector trigger
    ; T5 = R-arm Qsq scanner scint.
    ; T6 = L-arm Qsq scanner scint
    ; T7 = R-arm S2m trigger
    ; T8 = L-arm S2m trigger
    ; T9 = 10 Hz pulser (cannot be prescaled; don't even try)
    
    ps1=300,ps2=30,ps3=250,ps4=22,ps5=9999,ps6=9999,ps7=500,ps8=265
    
    
    Left septum set current : 257.786
    Left septum current readback : 253.784
    Left septum upper coil T : 6.16
    Left septum lower coil T : 6.206
    Right septum set current : 252.929
    Right septum current readback : 251.343
    Right septum upper coil T : 6.57
    Right septum lower coil T : 5.972
    Left Arm Q1 momentum : 2.73606
    Left Arm Q1 power supply : 1643
    Left Arm Q1 gauss meter : -0.13873
    Left Arm Q2 power supply current : 1187.16
    Left Arm Q2 momentum : 2.73571
    Left Arm Q2 gauss meter : 0.6249
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 950.551
    Left Arm D1 momentum : 2.73585
    Left Arm D1 NMR : 1.01283
    Left Arm Q3 power supply current : 1281.2
    Left Arm Q3 momentum : 2.73583
    Left Arm Q3 gauss meter : -0.6409
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.73211
    Right Arm Q1 power supply : 1633.23
    Right Arm Q1 gauss meter : -0.04064
    Right Arm Q2 power supply current : 1185.75
    Right Arm Q2 momentum : 2.73246
    Right Arm Q2 gauss meter : 0.6224
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 971.425
    Right Arm D1 momentum : 2.73199
    Right Arm D1 NMR : 1.01381
    Right Arm Q3 power supply current : 1279.26
    Right Arm Q3 momentum : 2.73176
    Right Arm Q3 gauss meter : 0.5741
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -0.488281
    Left Arm Bottom VDC Current : -0.976562
    Left Arm Top VDC voltage : 4.00098
    Left Arm Bottom VDC voltage : 3.99365
    Right Arm Top VDC voltage : 3.99072
    Right Arm Bottom VDC voltage : 3.99609
    RICH Vmon 16 : CAENdatC1M2Ch16.NLH --- Invalid channel name
    RICH Imon 16 : CAENdatC1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : CAENdatC1M2Ch17.NLH --- Invalid channel name
    RICH Imon 17 : CAENdatC1M2Ch17.NLK --- Invalid channel name
    RICH Radiator Oxygen : HacRICH_HPE1313A:0_RadO2 --- Invalid channel name
    RICH Radiator Moisture : HacRICH_HPE1313A:0_RadMoist --- Invalid channel name
    RICH Radiator Pressure : HacRICH_HPE1313A:0_Ch9 --- Invalid channel name
    RICH Condensor temperature : HacRICH_HPE1313A:0_Cond_Temp --- Invalid channel name
    RICH Gas Oxygen : HacRICH_HPE1313A:0_GasO2 --- Invalid channel name
    RICH Gas Moisture : HacRICH_HPE1313A:0_GasMoist --- Invalid channel name
    RICH Argon Flow : HacRICH_HPE1313A:0_Ch4 --- Invalid channel name
    RICH Methane Flow : HacRICH_HPE1313A:0_Ch5 --- Invalid channel name
    RICH A Volts : HacRICH_HPE1313A:0_Ch10 --- Invalid channel name
    RICH B Volts : HacRICH_HPE1313A:0_Ch11 --- Invalid channel name
    Average current of the two cavities : 1.939
    Current on Unser monitor : -0.0020125
    Current on Upstream bcm : 1.91503
    Current on Downstream bcm : 1.96296
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.4715
    Tiefenbach Hall A energy : 2753.03
    Tiefenbach Hall C energy : 1853.04
    Delta(E)/E width (MV_AI_DXWID) : 5.38189
    HALLA:p : 2753.03
    HALLA:dpp : -1.71008e-05
    MBSY1c Hall A Beam energy : 2757.26
    MBSY3c Hall C Beam energy : 1857.18
    MBSY1c magnet current (amp) : 114.771
    MBSY1c Bdl : 688077
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0572266
    HacL_HPE1313A:0_Ch58 : -0.180664
    HacL_HPE1313A:0_Ch55 : 25.9277
    HacL_HPE1313A:0_Ch54 : 0.0385742
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : 12.321
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 12.697
    IPM1C12.XPOS : -0.00469303
    IPM1C12.YPOS : 0.142795
    IPM1H04A.XPOS : 0.968845
    IPM1H04A.YPOS : -0.696749
    IPM1H04B.XPOS : 1.13022
    IPM1H04B.YPOS : 0.129317
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 69
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1250
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : Yes
    SLI horiz size mm : 0.266507
    SLI Energy spread *10^5 : 6.66267
    SLI x position : 1.29689
    SLI vert. size mm : 0.222778
    SLI y position : 1.36714
    Waterfall Pump Speed : HAWF_DAC1 --- Invalid channel name
    Target StepMot Pos. : HA_WF_motpos --- Invalid channel name