    User name a-onl

    Log entry time 00:48:51 on July 25, 2005

    Entry number 149354

    keyword=Start_Run_2263,Run_type=alignment,beam_energy=2.750,beam_raster=on,comment_text=+10% septum... hrs/septum scan. p0+2MeV,daq_mode=twoarm,kin_name=,leftarm_p=2.736,leftarm_theta=6.0,rightarm_p=2.732,rightarm_theta=6.0,target_type=Helium
    Beginning-of-run EPICS data for Run Number 2263 at Mon Jul 25 00:47:25 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm S0 trigger (new HAPPEX S0)
    ; T2 = R-arm HAPPEX detector trigger
    ; T3 = L-arm S0 trigger (new HAPPEX S0)
    ; T4 = L-arm HAPPEX detector trigger
    ; T5 = R-arm Qsq scanner scint.
    ; T6 = L-arm Qsq scanner scint
    ; T7 = R-arm S2m trigger
    ; T8 = L-arm S2m trigger
    ; T9 = 10 Hz pulser (cannot be prescaled; don't even try)
    
    ps1=540,ps2=87,ps3=523,ps4=91,ps5=10,ps6=10,ps7=616,ps8=600
    
    
    
    
    
    
    
    
    Left septum set current : 283.57
    Left septum current readback : 279.175
    Left septum upper coil T : 6.157
    Left septum lower coil T : 6.204
    Right septum set current : 278.22
    Right septum current readback : 274.414
    Right septum upper coil T : 6.556
    Right septum lower coil T : 5.978
    Left Arm Q1 momentum : 2.73784
    Left Arm Q1 power supply : 1644.07
    Left Arm Q1 gauss meter : -0.13879
    Left Arm Q2 power supply current : 1188.17
    Left Arm Q2 momentum : 2.73804
    Left Arm Q2 gauss meter : 0.6254
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 951.677
    Left Arm D1 momentum : 2.73805
    Left Arm D1 NMR : 1.01364
    Left Arm Q3 power supply current : 1282.24
    Left Arm Q3 momentum : 2.73812
    Left Arm Q3 gauss meter : -0.6413
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.73398
    Right Arm Q1 power supply : 1634.35
    Right Arm Q1 gauss meter : -0.04065
    Right Arm Q2 power supply current : 1186.6
    Right Arm Q2 momentum : 2.73441
    Right Arm Q2 gauss meter : 0.6229
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 973.525
    Right Arm D1 momentum : 2.734
    Right Arm D1 NMR : 1.01456
    Right Arm Q3 power supply current : 1280.55
    Right Arm Q3 momentum : 2.73452
    Right Arm Q3 gauss meter : 0.5748
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : -14.9902
    Left Arm Bottom VDC Current : -17.8223
    Left Arm Top VDC voltage : 3.99902
    Left Arm Bottom VDC voltage : 3.99316
    Right Arm Top VDC voltage : 4.00146
    Right Arm Bottom VDC voltage : 3.99072
    RICH Vmon 16 : CAENdatC1M2Ch16.NLH --- Invalid channel name
    RICH Imon 16 : CAENdatC1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : CAENdatC1M2Ch17.NLH --- Invalid channel name
    RICH Imon 17 : CAENdatC1M2Ch17.NLK --- Invalid channel name
    RICH Radiator Oxygen : HacRICH_HPE1313A:0_RadO2 --- Invalid channel name
    RICH Radiator Moisture : HacRICH_HPE1313A:0_RadMoist --- Invalid channel name
    RICH Radiator Pressure : HacRICH_HPE1313A:0_Ch9 --- Invalid channel name
    RICH Condensor temperature : HacRICH_HPE1313A:0_Cond_Temp --- Invalid channel name
    RICH Gas Oxygen : HacRICH_HPE1313A:0_GasO2 --- Invalid channel name
    RICH Gas Moisture : HacRICH_HPE1313A:0_GasMoist --- Invalid channel name
    RICH Argon Flow : HacRICH_HPE1313A:0_Ch4 --- Invalid channel name
    RICH Methane Flow : HacRICH_HPE1313A:0_Ch5 --- Invalid channel name
    RICH A Volts : HacRICH_HPE1313A:0_Ch10 --- Invalid channel name
    RICH B Volts : HacRICH_HPE1313A:0_Ch11 --- Invalid channel name
    Average current of the two cavities : 0.440554
    Current on Unser monitor : -1.51209
    Current on Upstream bcm : 0.435027
    Current on Downstream bcm : 0.446082
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 24.3502
    Tiefenbach Hall A energy : 2752.86
    Tiefenbach Hall C energy : 1853.05
    Delta(E)/E width (MV_AI_DXWID) : 1.9307
    HALLA:p : 2752.86
    HALLA:dpp : -8.1417e-05
    MBSY1c Hall A Beam energy : 2757.26
    MBSY3c Hall C Beam energy : 1857.18
    MBSY1c magnet current (amp) : 114.771
    MBSY1c Bdl : 688077
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0577148
    HacL_HPE1313A:0_Ch58 : -0.18457
    HacL_HPE1313A:0_Ch55 : 26.2207
    HacL_HPE1313A:0_Ch54 : 0.0380859
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : 12.321
    Right Arm Angle Floor Angle : 12.5
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 12.697
    IPM1C12.XPOS : 0.358555
    IPM1C12.YPOS : -0.188845
    IPM1H04A.XPOS : 1.64681
    IPM1H04A.YPOS : -0.0386918
    IPM1H04B.XPOS : -1.46353
    IPM1H04B.YPOS : 0.0487634
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -35.0008
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 23.26
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1250
    Beam Half-wave plate (off=out) : OUT
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.46832
    SLI vert. size mm : 0
    SLI y position : 1.23192
    Waterfall Pump Speed : HAWF_DAC1 --- Invalid channel name
    Target StepMot Pos. : HA_WF_motpos --- Invalid channel name