User name a-onl
Log entry time 14:51:38 on July 28, 2005
Entry number 149848
keyword=End_of_Run_2313
****************************
Run Number: 2313
End of Run Comment:
Run_type=spot++,beam_energy=2.750,beam_raster=on,comment_text=checking raster size with spot++,daq_mode=twoarm,kin_name=,leftarm_p=2.737,leftarm_theta=6.0,rightarm_p=2.733,rightarm_theta=6.0,target_type=No target
PRESCALE FACTORS:ps1=540 ps2=87 ps3=523 ps4=91 ps5=10 ps6=10 ps7=1 ps8=1
EVENTS[0]: 4200 [+]: 4136 [-]: 0
TIME [0]: 1.195 mins [+]: 1.249 mins [-]: 0.017 mins
TRIGGER RATES: PRES/REAL
T1[0] : 0.0/0.0 Hz T2[0] : 0.0/0.0 Hz T3[0] : 0.0/0.0 Hz T4[0] : 0.0/0.0 Hz T5[0] : 0.0/0.0 Hz T6[0] : 0.0/0.0 Hz T7[0] :58.6/58.6 Hz T8[0] :58.6/58.6 Hz
T1[+] : 0.0/0.0 Hz T2[+] : 0.0/0.0 Hz T3[+] : 0.0/0.0 Hz T4[+] : 0.0/0.0 Hz T5[+] : 0.0/0.0 Hz T6[+] : 0.0/0.0 Hz T7[+] :58.6/58.6 Hz T8[+] :58.6/58.6 Hz
T1[-] : 0.0/0.0 Hz T2[-] : 0.0/0.0 Hz T3[-] : 0.0/0.0 Hz T4[-] : 0.0/0.0 Hz T5[-] : 0.0/0.0 Hz T6[-] : 0.0/0.0 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 0/0 T2[0] : 0/0 T3[0] : 0/0 T4[0] : 0/0 T5[0] : 0/0 T6[0] : 0/0 T7[0] : 4200/4200 T8[0] : 4200/4200
T1[+] : 0/0 T2[+] : 0/0 T3[+] : 0/0 T4[+] : 0/0 T5[+] : 0/0 T6[+] : 0/0 T7[+] : 4391/4391 T8[+] : 4391/4391
T1[-] : 0/0 T2[-] : 0/0 T3[-] : 0/0 T4[-] : 0/0 T5[-] : 0/0 T6[-] : 0/0 T7[-] : 0/0 T8[-] : 0/0
AVERAGE CURRENT
BCM x1 : 5.1136 uA BCM x3 : 5.0150 uA BCM x10: 4.9996 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.046E+06 ppm BCM u3 :1.016E+06 ppm BCM u10:1.012E+06 ppm
BCM d1 : 1.01E+06 ppm BCM d3 :1.011E+06 ppm BCM d10:1.009E+06 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0003666 BCM u3 [0]:0.0003596 BCM u10[0]:0.0003571
BCM u1 [+]:0.0003833 BCM u3 [+]:0.000376 BCM u10[+]:0.0003734
BCM u1 [-]:-1.149E-07 BCM u3 [-]:-4.003E-08 BCM u10[-]:-2.898E-08
BCM d1 [0]:0.0003664 BCM d3 [0]:0.0003593 BCM d10[0]:0.0003596
BCM d1 [+]:0.0003831 BCM d3 [+]:0.0003757 BCM d10[+]:0.000376
BCM d1 [-]:-2.559E-08 BCM d3 [-]:-2.627E-08 BCM d10[-]:-2.334E-08
****************************
End-of-run EPICS data for Run Number 2313 at Thu Jul 28 14:51:33 EDT 2005
Left Arm D1 momentum : 2.73701
Left Arm arm angle : 12.321
Right Arm D1 momentum : 2.73299
Right Arm arm angle : 0
HALLA:p : 2753.25
HALLA:dpp : -1.31497e-05
Tiefenbach Hall A energy : 2753.23
Right Arm arm mispointing (HPT) : 0
Left Arm Top VDC Current : 0.78125
Left Arm Bottom VDC Current : 0.830078
Left septum set current : 283.57
Left septum current readback : 279.785
Left septum upper coil T : 6.17
Left septum lower coil T : 6.219
Right septum set current : 278.22
Right septum current readback : 274.658
Right septum upper coil T : 6.566
Right septum lower coil T : 5.957
Left Arm Q1 momentum : 2.73704
Left Arm Q2 power supply current : 1187.78
Left Arm Q2 momentum : 2.73714
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 951.184
Left Arm D1 momentum : 2.73701
Left Arm D1 NMR : 1.01325
Left Arm Q3 power supply current : 1281.61
Left Arm Q3 momentum : 2.73678
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.733
Right Arm Q1 gauss meter : -0.04064
Right Arm Q2 power supply current : 1185.94
Right Arm Q2 momentum : 2.7329
Right Arm Q2 gauss meter : 0.622
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 972.649
Right Arm D1 momentum : 2.73299
Right Arm D1 NMR : 1.01418
Right Arm Q3 power supply current : 1279.72
Right Arm Q3 momentum : 2.73276
Right Arm Q3 gauss meter : 0.574
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.0538
Current on Unser monitor : 2.25606
Current on Upstream bcm : 4.99062
Current on Downstream bcm : 5.11697
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 29.9503
Hall C Current : 24.1812
MBSY1c Hall A Beam energy : 2757.46
MBSY1c magnet current (amp) : 114.779
MBSY1c Bdl : 688127
MBSY3c Hall C Beam energy : 1857.18
Tiefenbach Hall A energy : 2753.25
Tiefenbach Hall C energy : 1853.09
Delta(E)/E width (MV_AI_DXWID) : 2.45132
IPM1C12.XPOS : 0.00705406
IPM1H04A.XPOS : 1.14017
IPM1H04A.YPOS : -0.0388589
IPM1H04B.XPOS : 0.353752
IPM1H04B.YPOS : -0.15288
Left Arm Collimator : 0.0581543
HacL_HPE1313A:0_Ch58 : -0.182129
HacL_HPE1313A:0_Ch55 : 26.5625
HacL_HPE1313A:0_Ch54 : 0.0341797