Log entry time 20:28:01 on August 1,2005
Entry number 150357
keyword=Status of Right Q2
Right Q3 tripped 3 times at about 1400A. The last
time we ramped it up by 100A increments with a few min in
between. Each time the "overheating" status had to be reset
in the hall.
Now we have the 3-rd control access because of this problem.
Heidi is in the hall.