    User name a-onl

    Log entry time 00:51:29 on August 14, 2005

    Entry number 151781

    keyword=Start_Run_2419,Run_type=spot++,beam_energy=2.750,beam_raster=on,comment_text=raster check,daq_mode=twoarm,kin_name=,leftarm_p=2.737,leftarm_theta=6.0,rightarm_p=2.733,rightarm_theta=6.0,target_type=Helium
    Beginning-of-run EPICS data for Run Number 2419 at Sat Aug 13 20:36:40 EDT 2005
    
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite. 
    ; T1 = R-arm S0 trigger (new HAPPEX S0)
    ; T2 = R-arm HAPPEX detector trigger
    ; T3 = L-arm S0 trigger (new HAPPEX S0)
    ; T4 = L-arm HAPPEX detector trigger
    ; T5 = R-arm Qsq scanner scint.
    ; T6 = L-arm Qsq scanner scint
    ; T7 = R-arm S2m trigger
    ; T8 = L-arm S2m trigger
    ; T9 = 10 Hz pulser (cannot be prescaled; don't even try)
    
    ;ps=50,ps2=50,ps3=50,ps4=50,ps5=10,ps6=10,ps7=100,ps8=100
    ps1=1,ps2=1,ps3=1,ps4=1,ps5=10,ps6=10,ps7=1,ps8=1
    
    
    
    
    
    Left septum set current : 283.57
    Left septum current readback : 277.954
    Left septum upper coil T : 6.162
    Left septum lower coil T : 6.234
    Right septum set current : 278.22
    Right septum current readback : 274.658
    Right septum upper coil T : 6.472
    Right septum lower coil T : 5.982
    Left Arm Q1 momentum : 2.73713
    Left Arm Q1 power supply : 1643.59
    Left Arm Q1 gauss meter : -0.13874
    Left Arm Q2 power supply current : 1187.8
    Left Arm Q2 momentum : 2.73718
    Left Arm Q2 gauss meter : 0.6253
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 951.684
    Left Arm D1 momentum : 2.73701
    Left Arm D1 NMR : 1.01326
    Left Arm Q3 power supply current : 1281.74
    Left Arm Q3 momentum : 2.73707
    Left Arm Q3 gauss meter : -0.6413
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.733
    Right Arm Q1 power supply : 1633.76
    Right Arm Q1 gauss meter : -0.0407
    Right Arm Q2 power supply current : 1185.95
    Right Arm Q2 momentum : 2.73293
    Right Arm Q2 gauss meter : 0.6225
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 972.439
    Right Arm D1 momentum : 2.73299
    Right Arm D1 NMR : 1.01418
    Right Arm Q3 power supply current : 1279.63
    Right Arm Q3 momentum : 2.73257
    Right Arm Q3 gauss meter : 0.5743
    Right Arm Q3 power supply polarity : disabled
    Left Arm Top VDC Current : 0.78125
    Left Arm Bottom VDC Current : 0.78125
    Left Arm Top VDC voltage : 0.0112305
    Left Arm Bottom VDC voltage : 0.0117188
    Right Arm Top VDC voltage : -0.00732422
    Right Arm Bottom VDC voltage : 0.00488281
    RICH Vmon 16 : CAENdatC1M2Ch16.NLH --- Invalid channel name
    RICH Imon 16 : CAENdatC1M2Ch16.NLK --- Invalid channel name
    RICH Vmon 17 : CAENdatC1M2Ch17.NLH --- Invalid channel name
    RICH Imon 17 : CAENdatC1M2Ch17.NLK --- Invalid channel name
    RICH Radiator Oxygen : HacRICH_HPE1313A:0_RadO2 --- Invalid channel name
    RICH Radiator Moisture : HacRICH_HPE1313A:0_RadMoist --- Invalid channel name
    RICH Radiator Pressure : HacRICH_HPE1313A:0_Ch9 --- Invalid channel name
    RICH Condensor temperature : HacRICH_HPE1313A:0_Cond_Temp --- Invalid channel name
    RICH Gas Oxygen : HacRICH_HPE1313A:0_GasO2 --- Invalid channel name
    RICH Gas Moisture : HacRICH_HPE1313A:0_GasMoist --- Invalid channel name
    RICH Argon Flow : HacRICH_HPE1313A:0_Ch4 --- Invalid channel name
    RICH Methane Flow : HacRICH_HPE1313A:0_Ch5 --- Invalid channel name
    RICH A Volts :
    RICH B Volts :
    Average current of the two cavities : 16.7137
    Current on Unser monitor : 18.8283
    Current on Upstream bcm : 12.5547
    Current on Downstream bcm : 20.8727
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 28.3303
    Tiefenbach Hall A energy : 2753.24
    Tiefenbach Hall C energy : 1853.1
    Delta(E)/E width (MV_AI_DXWID) : 0
    HALLA:p : 2753.24
    HALLA:dpp : -2.77089e-05
    MBSY1c Hall A Beam energy : 2757.5
    MBSY3c Hall C Beam energy : 1857.18
    MBSY1c magnet current (amp) : 114.781
    MBSY1c Bdl : 688137
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.0576172
    HacL_HPE1313A:0_Ch58 : -0.192383
    HacL_HPE1313A:0_Ch55 :
    HacL_HPE1313A:0_Ch54 :
    Left Arm Angle Floor Angle :
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : 12.321
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0
    IPM1C12.XPOS : 0.0728558
    IPM1C12.YPOS : 0.167872
    IPM1H04A.XPOS : 1.53662
    IPM1H04A.YPOS : 0.0411205
    IPM1H04B.XPOS : -1.40277
    IPM1H04B.YPOS : -0.00885344
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field :
    Laser attenuation Hall A : 157
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 5600
    Beam Half-wave plate (off=out) : IN
    SLI data valid? : Yes
    SLI horiz size mm : 0.198792
    SLI Energy spread *10^5 : 4.65053
    SLI x position : 1.20745
    SLI vert. size mm :
    SLI y position : 1.41972
    Waterfall Pump Speed :
    Target StepMot Pos. : HA_WF_motpos --- Invalid channel name