Left HRS p0 = -2.737 GeV/c Septum Set Current = 283.57A
Right HRS p0 = -2.733 GeV/c Septum Set Current = 278.22A
Sweeper is ON at 111.00A
Summary
Mostly production (production runs 5136-5147: 284.0k pairs ~= 0.76C). Spent a couple of hours
doing some profile scans at different spectrometer momentum settings.
Significant Events
- 00:00 Began shift with the start of run
5136, compton run 12207. IHWP IN.
- 00:20 Asked MCC to increase beam current
to 40µA (from 38µA).
- 03:44 Begin profile scans at different
momentum settings.
- 03:56 Cycle Q2 and Q3 to prepare for
higher momentum runs.
- 04:32 Noticed that the right arm Q1 would
not change to the new momentum settings. Ignored it.
- 05:00 Right Q1 dropped its current to
zero (slowly). Reset it with the posted procedure, and set its
current by hand.
- 05:38 Return magnets to nominal
setpoints.
- 05:40 Incoming Call: R. Suleiman:
Status Update
- 05:51 Asked MCC to retract the IHWP.
Back to production.
- 07:30 Compton DAQ crashes hard. ROCs will
not respond to reboot.
Data Run Summary
- 00:00 Run 5136 -
Production Run (20cm Helium-4), IHWP IN, 48.9k pairs.
- 00:55 Run 5137 -
Production Run (20cm Helium-4), IHWP IN, 46.7k pairs.
- 01:51 Run 5138 -
Production Run (20cm Helium-4), IHWP IN, 47.9k pairs.
- 02:47 Run 5139 -
Production Run (20cm Helium-4), IHWP IN, 48.0k pairs.
- 03:44 Run 5140 -
Profilescan (20cm Helium-4), IHWP IN. 0% of nominal momentum.
- 04:14 Run 5141
- Profilescan (20cm Helium-4), IHWP IN. +2% of nominal
momentum. Right arm still ramping.
- 04:37 Run 5142 -
Profilescan (20cm Helium-4), IHWP IN. +1% of nominal momentum. Right Q1 wrong.
- 04:52 Run 5143 -
Profilescan (20cm Helium-4), IHWP IN. +0.5% of nominal momentum. Right Q1 wrong.
- 05:14 Run 5144 -
Profilescan (20cm Helium-4), IHWP IN. -10MeV of nominal momentum. Right Q1 wrong.
- 05:39 Run 5145 -
Profilescan (20cm Helium-4), IHWP IN. 0% of nominal momentum.
- 05:54 Run 5146 -
Production Run (20cm Helium-4), IHWP OUT, 47.8k pairs.
- 06:50 Run 5147 -
Production Run (20cm Helium-4), IHWP OUT, 44.7k pairs.
- 07:46 Run 5148 -
Production Run (20cm Helium-4), IHWP OUT. Passed to day shift.
Compton Data Run Summary
- 00:00 Run 12208
- IHWP IN. ROC2 in disconnected state. Barely any
coincidence rate with cavity on.
- 00:35 Run 12209
- IHWP IN, Beam polarization = -82.5%,
- 02:39 Run 12210
- IHWP IN, Beam polarization = -82.4%,
- 05:46 Run 12211
- IHWP OUT. ROC5 crashed. CODA rebooted, but ROCS will not
reboot.
|