We did some more Q2 scanner studies, adjusting quads
Q1, Q2, Q3. These revealed that the infamous "shoulder" in the
X-Y distribution of the elastic peak is a universal feature of
both HRS which can be made bigger or very small (vanishing) by
adjusting the quads.
Then we did 2 production runs. IWHP in. Flippered at 04:40
Run 5439 ... 49K good pairs
Run 5440 ... 48K good pairs (we let DAQ run to 103K at 07:00)
At 07:00 beam is taken away. Target put to empty position.
Hall A to controlled access as per the plan. Target warmup is
supposed to happen soon ... expert not here yet.
That's the end of Happex-4He !!
We resume data taking with HAPPEX-H on Oct 13.