• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Moffit

    Log entry time 16:46:13 on October12,2005

    Entry number 156639

    keyword=HAPPEX detector signals to HAPPEX and HRS DAQ

    Here's the detector signal setup to both DAQs:
      
      Left arm
                 HRS DAQ       HAPPEX DAQ    HV channel
    vert seg.   descrim ch.1    adc27_0      Slot 10 ch. 8
    horz seg.   descrim ch.3    adc27_1      Slot 10 ch. 9
    scint scan  descrim ch.4                 Slot 10 ch.10
    quartz scan                 adc27_3      Slot 10 ch.11
    
    Right arm
    vert seg.   descrim ch.1    adc28_0      Top Slot 11 ch.10
    horz seg.   descrim ch.3    adc28_1      Top Slot 11 ch.11
    scint scan  descrim ch.4                 Top Slot 10 ch.10
    quartz scan                 adc28_3      Top Slot 10 ch.11
    
    The vertical segment should be the high q2 (low rate) detector
    The horizonal segment should be the low q2 (high rate) detector