User name D. Lhuillier
Log entry time 23:13:31 on October15,2005
Entry number 156992
keyword=Turn right septum ON
The fact that the right septum is off changes the rates in the left arm and the radiation level in the dump. The alignment check and background studies we want to do tonight should be done in running conditions similar to production. Therefore we stopped the beam for a while, wait the right septum to cool down before turning it ON.
Ed was concerned that if we turned ON the septum and not the HRS we might send to much radiation to the detector package but I think that the dangerous situation is rather HRS ON and septum OFF.
Right septum is ramping up now.