User name R. Feuerbach
Log entry time 03:30:16 on October 19, 2005
Entry number 157368
This entry is a followup to: 156948
keyword=Alignment check
Using the Q2 run 2873 taken this evening, the alignment of the
elastic peak on the HAPPEX detectors has been checked; it looks very
good, with an ~2cm gap between the edge of the detectors' sensitive
region (in the dispersive direction) and the edge of the elastic stripe.
Figure 1 shows the distribution of events in the L-HRS, and figure two is
for the R-HRS. An explanation of the panels can be found in HALOG entry
156948.
Run 2873 was taken with momentum settings (for the Tools screen) of
3.1234 for the L-HRS, and 3.1126 GeV/c for the R-HRS. No changes are
necessary.
Figure 1: L-HRS distributions

Figure 2: R-HRS distributions