Log entry time 07:02:56 on October21,2005
Entry number 157572
keyword=magnet problems
Various problems.
1. Right Q2 quench. Would not clear remotely. Went into hall and
reset RQ2 (instructions are posted at power supply). It came up.
2. When we brought Q2 back up, we cycled Q2 and got an "overtemp-
erature" fault which would not clear remotely, requiring another
access. Perhaps it was stupid but this cycle procedure is usually
no problem. Won't do that again - I don't think we need to cycle
quads.
3. Lost IOCHA49. Rebooted via hareboot7 as per instructions in
the trouble-shooting guide. Fine again.