• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 07:02:56 on October21,2005

    Entry number 157572

    keyword=magnet problems

    Various problems.

    1. Right Q2 quench. Would not clear remotely. Went into hall and
    reset RQ2 (instructions are posted at power supply). It came up.

    2. When we brought Q2 back up, we cycled Q2 and got an "overtemp-
    erature" fault which would not clear remotely, requiring another
    access. Perhaps it was stupid but this cycle procedure is usually
    no problem. Won't do that again - I don't think we need to cycle
    quads.

    3. Lost IOCHA49. Rebooted via hareboot7 as per instructions in
    the trouble-shooting guide. Fine again.